期刊文献+

下水道处理生活污水技术强化模拟实验研究

Enhancement of simulated experiment research on the treatment of domestic sewage in sewer lines
下载PDF
导出
摘要 在温度20℃、流速0.3 m/s、pH=7.0、挂膜密度为10 L-1条件下,改变DO及MLSS浓度开展下水道处理生物污水技术强化模拟实验。实验结果表明,提高待处理水样的DO,有利于对污染物的去除,适宜的DO为3.0 mg/L,此时系统对COD、TN、TP的去除率分别达到67%、21%、12%;在一定范围内增加MLSS可以持续提高处理系统对污水的净化能力,适宜的MLSS为2.0 g/L,此时COD、TN、TP的去除率分别达到60%、40%、15%。 The enhancement of simulated experiment research on the treatment technology of domestic sewage in sewer lines have been developed, under the following conditions:temperature 20 ℃, flow rate 0.3 m/s, pH=7.0, density of membranes on suspended carrier 10 L^-1 ,and change the DO and MLSS concentrations. The results show that increasing the DO of water samples to be treated is benefical for the removal of pollutants. When the appropriate DO is 3.0 mg/L,the COD, TN and TP removing rates can reach 67%, 21%, 12%, respectively. In a certain range, in- creasing MESS can continuously improve the cleaning capacity of the treatment system for sewage. When the apppropriate MLSS is 2.0 g/L, the removing rates of C OD,TN and TP can reach 60%, 40%, 15%, respectively.
机构地区 桂林理工大学
出处 《工业水处理》 CAS CSCD 北大核心 2014年第3期26-28,共3页 Industrial Water Treatment
基金 国家水体污染控制与治理科技重大专项(2008ZX07317-02-03-05) 教育部科学技术研究重点项目(教技司〔2010〕114号 210170) 广西高校优秀人才资助计划项目(桂教人[2010]65号)
关键词 下水道 生活污水 废水处理 技术强化 sewer lines domestic sewage wastewater treatment technique enhancement
  • 相关文献

参考文献10

二级参考文献22

  • 1陈辅利,中国专利,溪流式生物接触氧化污水处理构筑物 被引量:1
  • 2卞涛,中国专利,一种高浓度有机污水处理新方法 被引量:1
  • 3顾夏声,废水生物处理数学模式,1993年 被引量:1
  • 4卞涛,专利号96103295.2 被引量:1
  • 5Kalmbach S,Manz W,BendingerB,et al.In situ probing reveals aqua-bacterium commune as a widespread and highly abundant bacterial species in drinking water biofilms[J].Wat Res,2000,34(2):575-581. 被引量:1
  • 6Macdonald R,Brozel V S.Community analysis of bacterial biofilms in a simulated recirculating cooling-water system by fluorescent in situ hybridization with RNA-targeted oligonucleotide probes[J].Wat Res,2000,34(9):2439-2446. 被引量:1
  • 7Camper A K,LeChevallier M W,Broadway S C,et al.Bacteria Associated with Granular Activated Carbon Particles in Drinking Water[J].Applied and Environmental Microbiology,1986,52(3):434-438. 被引量:1
  • 8Tsai Y P,Pai T Y,Qiu J M.The impacts of the AOC concentration on biofilm formation under higher shear force condition[J].Journal of Biotechnology,2004,111(2):155-167. 被引量:1
  • 9O'Shaughnessy P T,Barsotti M G,Fay J W,et al.Evaluating particle counters[J].Journal American Water Works Association,1997,89(12):60-76. 被引量:1
  • 10LeChevallier M W,William D N.Examining relationships between particle counts and giardia,cryptosporidium and turbidity[J].Journal American Water Works Association,1992,84(12):54-60. 被引量:1

共引文献37