摘要
采用Fenton氧化预处理和微滤对焦化厂厌氧-缺氧-好氧工艺(A2 O)出水进行处理,研究Fenton氧化对水质的影响,考察Fenton氧化减缓膜污染的效果.结果表明,A2 O出水经Fenton氧化后,COD和矿物油的去除率均达到70%以上,UV254的去除率达到47%,浊度和悬浮固体去除率都达到80%以上;膜过滤的总阻力降低了92.1%,可有效控制膜污染.
The Anaerobic-Anoxic-Oxic(A2 O) drainage from coking plant was treated by the Fenton regent pretreatment and microfiltration. The effects of oxidation on the water quality and membrane fouling were investigated. The experiment results showed that the removal rate of the COD and mineral oil were above 70%, the removal rate of UV254 was 47%, and the removal rate of turbidity and suspended solids were above 80%. The resistance of membrane filtration decreased by 92. 1% and the membrane fouling was controlled effectively.
出处
《膜科学与技术》
CAS
CSCD
北大核心
2014年第1期104-110,共7页
Membrane Science and Technology
基金
国家科技支撑计划:钢铁联合企业综合废水深度处理及循环回用技术及应用(2012BAC02B04)