期刊文献+

基于双馈感应发电机风电场等效建模中控制器聚合方法分析 被引量:11

Analysis on Controller Aggregation Method for Equivalent Modeling of DFIG-based Wind Farm
下载PDF
导出
摘要 在对风电场进行等效建模时,一般以风电机组运行状态相近为原则进行分群聚合,从而得到风电场的多机等效模型。如果在保证精度的情况下能够对运行状态有明显差异的风电机组进行聚合,将有助于建立更加简化的风电场等效模型。以基于双馈感应发电机(DFIG)的风电场为研究对象,针对承受风速有显著差异的DFIG机组的聚合问题,提出了相应的DFIG机组转子侧控制器聚合方法。该方法通过调整等效控制器的控制参考值,来提高风电场等效模型的稳态和动态精度,从而实现风速差异显著的DFIG机组的聚合。文中给出了基于控制参数调整的DFIG风电场单机等效建模流程,为建立具有良好精度的风电场等效模型提供了一种不同于分群聚合的思路。最后,通过仿真算例对所提方法进行了分析和验证。 Clustering and aggregating the wind turbine generators with similar operation state is common in the wind farm equivalent modeling,which can obtain a multi-machine equivalent model of the wind farm.A more simplified equivalent model can be obtained if wind turbine generators in different operation states can be aggregated with satisfied accuracy.This paper is focused on the equivalent modeling of doubly-fed induction generators(DFIGs)with significant difference in wind speeds.An aggregation method of rotor-side controller of DFIG is proposed.The reference value of the aggregated rotor-side controller will be modified to improve both the steady and dynamic accuracy of the equivalent model.Thus,the aggregation of DFIGs under different wind speeds can be achieved.And a procedure for obtaining a single-machine equivalent model of a DFIG-based wind farm is also proposed.The proposed method brings a new way to build a more simplified equivalent model of the wind farm, which is different from the clustering and aggregation method.A case study is used to test and verify the proposed method.
出处 《电力系统自动化》 EI CSCD 北大核心 2014年第3期19-24,共6页 Automation of Electric Power Systems
基金 国家高技术研究发展计划(863计划)资助项目(2011AA05A103) 国家自然科学基金重大项目(51190102)~~
关键词 风力发电 双馈感应发电机 风电场 等效建模 控制器 聚合模型 wind power doubly-fed induction generator(DFIG) wind farm equivalent modeling controller aggregated model
  • 相关文献

参考文献14

二级参考文献210

共引文献854

同被引文献120

  • 1孙勇,景博.基于支持度的多传感器一致可靠性融合[J].传感技术学报,2005,18(3):537-539. 被引量:38
  • 2胡振涛,刘先省.基于相对距离的一种多传感器数据融合方法[J].系统工程与电子技术,2006,28(2):196-198. 被引量:28
  • 3胡杰,余贻鑫.电力系统动态等值参数聚合的实用方法[J].电网技术,2006,30(24):26-30. 被引量:74
  • 4Slootweg J G, Kling W L. Aggregated modelling of wind parks in power system dynamics simulations[C]//2003 IEEE Power Tech Conference. Bologna, Italy: IEEE, 2003: 1-6. 被引量:1
  • 5Fernandez L M, Jurado F, Saenz J R. Aggregated dynamic model for wind farms with doubly fed induction generator wind turbines[J]. Renewable Energy, 2008, 33(1): 129-140. 被引量:1
  • 6Fernandez L M, Garcia C A, Saenz J R, et al. Equivalent models of wind farms by using aggregated wind turbines and equivalent winds[J]. Energy Conversion and Management, 2009, 50(3): 691-704. 被引量:1
  • 7Fernandez L M, Garcia C A, Saenz J R, et al. Reduced model of DFIGs wind farms using aggregation of wind turbines and equivalent wind[C]//2006 IEEE MELCON. Benalmadena(Malaga), Spain: IEEE 2006:881-884. 被引量:1
  • 8Henneaux P, Labeau P E, Maun J C. Blackout probabilis- tic risk assessment and thermal effects : impacts of chang- es in generation[J]. IEEE Trans on Power Systems, 2013, 28(4) :4722-4731. 被引量:1
  • 9Gu X, Zhong H. Optimization of network reconfiguration based on a two-layer unit-restarting framework for power system restoration[J], lET Generation, Transmission & Distribution, 2012,6 (7) : 693-700. 被引量:1
  • 10Wang Chong, Vittal Vijay, Kolluri Venkat Sharma, et al. PTDF-based automatic restoration path selection[J]. IEEE Trans on Power Systems, 2010,25 (3) : 1686-1695. 被引量:1

引证文献11

二级引证文献95

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部