期刊文献+

家畜背膘厚与眼肌面积的B超测量技术 被引量:8

B-ultrasonic Measuring Technology of Livestock Backfat Thickness and Eye Muscle Area
下载PDF
导出
摘要 结合家畜的育种工作需求,介绍了兽用B超的理论基础、工作原理与测量方法,为推广应用背膘厚与眼肌面积的B超测量技术提供参考。 Combined with demand of livestock breeding work ,the theory foundation of veterinary B-ultrasound working principle and measuring method were introduced so as to provide the reference to promote application of backfat thickness and eye muscle area of B-ultrasonic measurement technology.
出处 《现代农业科技》 2014年第2期298-299,共2页 Modern Agricultural Science and Technology
基金 现代农业产业技术体系建设专项资金(nycytx-38) "国家科技支撑计划"新疆牛肉安全高效生产关键技术研究与示范"(2011BAD47B00) 自治区科技重大专项课题"新疆肉牛新品种(系)培育与杂交改良技术研究示范"(201230116-10)
关键词 背膘厚 眼肌面积 B超 测量技术 backfat thickness eye muscle area B-ultrasonic measuring technology
  • 相关文献

参考文献8

二级参考文献11

  • 1Crews D H J, Pollak E J, Quaas R L. Evaluation of simmental carcass EPD estimated using live and carcass data[J]. J Anim Sci,2004,82(3) :661-667. 被引量:1
  • 2Goddard P J. In veterinary ultrasonography. CAB International, Wallingford, UK, 1995. 被引量:1
  • 3Gresham J D. Introduction to characterization of live beef muscle tissue by use of the Pie 200 Scanner quality indexing program: An automated system for estimating quality grade of beef ani reals. The Ultrasound Review, Classic Ultrasound Equipment, 19900 Mona Road, Suite 105,Tequesta,FL 33469,1996. 被引量:1
  • 4Gresham J D. Ultrasonography as an objective tool for evaluating live beef cattle; Using the Pie Scanner 200 Ultrasound Scanner. The Ultrasound Review, Classic Ultrasound Equipment, 19900 Mona Road,Suite 105,Tequesta,FL 33469,1995. 被引量:1
  • 5Wild J J. The use of ultrasonic pulses for the measurement of biological tissues and the detection of tissue density changes. Surgery, 1950,27: 183-188. 被引量:1
  • 6Crews, D. H. Jr., E. J. Pollak and R. L. Quaas. Evaluation of Simmental carcass EPD estimated using live and carcass data[J]. J. Anim. Sci, 2004, 82:661-667. 被引量:1
  • 7Wild, J.J. The use of ultrasonic pulses for the measurement of biological tissues and the detection of tissue density changes[J]. Surgery, 1950, 27:183. 被引量:1
  • 8Goddard, P. J. In Veterinary Ultrasonography. CAB International, Wallingford, UK. 1995. 被引量:1
  • 9Powis, R. L. Personal Communication. 1996. 被引量:1
  • 10Gresham, J. D. Ultrasonography as an objective tool for evaluating live beef cattle: Using the Pie Scanner 200 Ultrasound Scanner. The Ultrasound Review. Classic Ultrasound Equipment, 19900 Mona Road, Suite 105, Tequesta, FL 33469. 1995. 被引量:1

共引文献40

同被引文献81

引证文献8

二级引证文献23

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部