摘要
对架空供热管道的设计要点进行探讨,包括:管道净高、保温材料选择、保护层设计、补偿器选择、旋转补偿器旋转臂最小长度及最佳安装角、活动支架允许间距、滑板长度设计。
The key design points of overhead heat-supply pipeline are discussed. These points in- elude clear height of pipeline, selection of thermal insulation material, design of protective layer, choice of compensator, design of minimum length and optimal installation angle of rotating arm of rotating compensa- tor, design of permissible distance between movable supports and design of length of sliding plate.
出处
《煤气与热力》
2014年第2期12-15,共4页
Gas & Heat
关键词
架空敷设
供热管道
设计要点
overhead installation
heat-supply pipeline
key design points