期刊文献+

伸顶通气管道系统中瞬间流排水特性的影响因素研究(一) 坐便器排水高度对排水管道系统压力的影响 被引量:8

Study on the influent factors on the instantaneous flow drainage in stack vent system(one):impact of toilet drainage height on drainage pipe system pressure
下载PDF
导出
摘要 以坐便器排水作为研究对象,通过改变坐便器的排水高度,结合不同层间排水时间间隔,探究排水高度对系统最大压力的影响。通过线性回归分析与方差分析,发现系统最大负压值与坐便器排水高度间存在显著的线性关系,不同排水高度与系统最大正压值没有显著的线性关系,但存在非常显著的影响。 The effect of drainage height to the maximum pressure of drainage pipe system was discovered by altering the drainage height of toilets with different time intervals between floors.The result of linear regression analysis showed that there was significant linear relationship between drainage height and maximum negative pressure of the system;while there was no significant linear relationship between drainage height and maximum positive pressure.However,drainage height had very significant impact on the maximum positive pressure according to the ANOVA analysis.
出处 《给水排水》 CSCD 北大核心 2014年第2期91-94,共4页 Water & Wastewater Engineering
关键词 伸顶通气 瞬时排水 排水高度 系统压力 线性回归分析 Stack vent system Instantaneous flow Drainage height System pressure Linear regression analysis
  • 相关文献

参考文献3

  • 1日本空调和卫生工程学会.公寓住宅的排水立管系统的排水能力试验方法[S]. 被引量:1
  • 2张晓燕..高层建筑排水管道内气压波动情况的研究[D].同济大学,2006:
  • 3王增长.建筑给水排水工程[M]{H}北京:中国建筑工业出版社,2010. 被引量:1

同被引文献39

引证文献8

二级引证文献23