摘要 目的评价流式荧光发光法在AFP、CEA、CA125、CA199定量测定中的可靠性。方法在Luminex 200多功能流式点阵仪上评价了本法的精密度、准确度(回收实验)、检出限、线性和抗干扰性,并分析了本法与电化学发光法检测结果的相关性。结果批内变异系数均小于10%,批间变异每米均小于13%,回收率在89%~113%之间,灵敏度较好,线性良好(r>0.99),血红蛋白、胆红素、三酰甘油对测定结果无显著性干扰(P>0.05),与电化学发光法检测结果相关性良好(r>0.975)。结论本方法测定结果准确、可靠,操作简便、快速,适宜于临床检测推广。 Objective To evaluate the reliability of the quantitative determination of tumor markers AFP, CEA, CA125 and CA199 based on the flow cytometry fluorescence method. Methods The precision, accuracy, sensitivity, linearity and interference resistance of the kits were evaluated with the automated analyzed Luminex 200 as determination instrument,and the correlation of the results were analysis with that of electrochemiluminescence. Results The chemical character evaluation showed that the within --run and between--run coefficients of variation(CV) were less than 10~ and 13~/00, respectively. The recovery rate was between 89^- 113~/00 ,and the sensitivity was high. The results demonstrated excellent linearity(r^0.99). The assay had no significant in terference by haemoglobin (Hb),bilirubin (Bil) and trig lyceride (TG) (P〉0.05). The correlation between the evaluated kits and electrochemiluminescen was excellent (r〉0. 975). Conclusion The quantitative assay is safe,accurate and easy to operate,and it is worthy to extend in clinical application.
作者 李洪涛 高庭
出处 《国际检验医学杂志》 CAS 2014年第2期203-204,207,共3页 International Journal of Laboratory Medicine
关键词 实验室技术和方法 肿瘤标记 生物学 流式荧光发光法 laboratory techniques and procedures tumor markers,biological flow cytometry fluorescence luminescence as-
  • 相关文献

参考文献12

  • 1Seideman J, Peritt D. A novel monoclonal antibody screening method using the Luminex-lO0 microsphere system[J]. J Immu- nol Methods,2002,267(2) : 165-171. 被引量:1
  • 2Dunbar SA. Applications of LuminexR xMAP technology for ra pid, high throughput raultiplexed nucleic acid detection [J]. Clin Chim Acta,2006,363(1/2) : 71-82. 被引量:1
  • 3Croft H,Malinowski T,Krizbai L,et al. Use of Luminex xMAP derived Bio-Plex bead based suspension array for specific detection of PPV W and characterization of epitopes on the coat protein of the virus[J]. J Virol Methods,2008,153(2):203-213. 被引量:1
  • 4Giavedoni LD. Simultaneous detection of multiple eytokines and chemokines from nonhuman primates using Luminex technology [J]. J ImmunolMethods,2005,301(1/2):89 -101. 被引量:1
  • 5姚见儿.Luminex高通量检测技术的应用和挑战[J].临床检验杂志,2010,28(4):250-251. 被引量:11
  • 6张保强,张晓.Luminex液态芯片在临床及科研中的应用[J].当代医学,2012,18(4):18-20. 被引量:13
  • 7National Committee for Clinical Laboratory Standards. Prelimina ry evaluation of quantitative clinical laboratory methods [S]. EP10 A2,NCCLS,2002. 被引量:1
  • 8National Committee forl:linical Laboratory Standards. Evaluation of the linearity of quantitative measurement procedures:a statisti- cal approach[S]. EP6 A2, NCCLS, 2003. 被引量:1
  • 9National Committee for Clinical Laboratory Standards. Interfe- rence testing in clinical chemistry: proposedguide line[S]. EPT-P, NCCLS, 1986. 被引量:1
  • 10National Committee for Clinical Laboratory Standards. Method comparison and bias estimation using patient samples[S]. EP9 A, NCCLS, 1995. 被引量:1

二级参考文献1

共引文献22

同被引文献80

引证文献5

二级引证文献42

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部