摘要
锅炉炉顶吊挂装置的振动行为关系到锅炉安全运行。文中采用敲击法测量的炉顶吊挂装置的固有频率,对比分析吊挂装置振动时的行为及原因,提出抑制其振动的办法,并通过实施验证治理效果。
The vibration of hanger rods on boiler is related to the boiler safety operation since the affection of excitation power from operating boiler. The analysis of natural frequency data of hanger rods by hammering method and of reason of vibration behavior are given in this paper. And then, the vibration control measures are reviewed and the results show that with effects against vibration.
出处
《应用能源技术》
2014年第1期26-27,共2页
Applied Energy Technology
关键词
锅炉
吊挂装置
固有频率
振动
Boiler
Hanger rod on boiler roof
Natural frequency
Vibration