摘要 随着原料性质不断变化以及硫质量分数的增加(由原来的0.4%上升至0.9%),导致催化裂化装置反再系统设备和管线腐蚀速度加剧。为及时掌握反再系统设备和管线的腐蚀情况,对催化裂化装置反再系统腐蚀机理、易腐蚀部位及防护措施进行了分析,另外也对催化裂化装置反再系统易发生腐蚀部位进行了案列分析并提出了相应的防护措施。近两年来装置反再系统腐蚀有所控制,实现装置连续两年长周期运行。 Tile conosion speed of equipment and pipelines in FCCU reactor and regenerator system became increasingly faster with frequent changes of FCC feedstock properties and increased weight percentage of sulfur (which was increased to 0.9% from 0.4% ). In order to know the corrosion conditions in the equipment and pipelines in FCCU reactor and regenerator system in a timely manner, the corrosion mechanisms and locations subject to corrosion in FCCU reactnr and regenerator system as well as protection measures were analyzed. Corrosinn cases were studied and corresponding corrosion protection measures were recommended. After implementation of these measures, the corrosion in the reactor - regenerator system has been brought under control, and FCC unit has been operating smoothly for two years.
出处 《石油化工腐蚀与防护》 CAS 2013年第6期33-35,共3页 Corrosion & Protection In Petrochemical Industry
关键词 腐蚀 反再系统 失效 防护措施 corrosion, reactor - regenerator system, failure, protection measures
  • 相关文献

参考文献2

  • 1顾望平;邵祖光;刘积文.炼油设备工程师手册[M]{H}北京:中国石化出版社,2010774-815. 被引量:1
  • 2龚敏;余祖孝;陈琳.金属腐蚀理论及腐蚀控制[M]{H}北京:化学工业出版社,200986-94. 被引量:1

同被引文献13