通过分析了工频磁场对单相电子式电能表的影响机理,以单相电子式电能表现场安装环境为基础,在实验室搭建仿真平台,对单相电子式电能表进行工频磁场环境下的无负载实验,寻找单相电子式电能表计量准确性与励磁电流、功率因数角的关系,确定工频磁场对单相电子式电能表最不利的相位和方向的条件,同时提出减小工频磁场对单相电子式电能表计量准确性影响的建议。
The influence mechanism of power-frequency magnetic field on single phase Watt-hour meter is analyzed. On the basis of meter installation environment, the simulation platform is set up in the laboratory. The power factor test under no-load condition is conducted under the environment of power-frequency magnetic field to find the relationship of Watt-hour meter error to exciting current and power factor angle. The worst conditions of phase and the direction for Watt-hour meter measurement in the environment are determined, and the suggestion that reduce the influence of power-frequency magnetic field on electrical meter measuring accuracy is made.