基于ECT的高速数据采集系统设计 被引量:5

ECT-based high-speed data acquisition system design
下载PDF
导出
摘要 数据采集系统的速度制约了电容层析成像技术在航空发动机气路监测系统等高速设备中的应用。为此,设计了一种基于FPGA的新型电容数据采集系统,采用DDR2存储技术和PCI总线技术实现了数据的高速传输。同时应用卡尔曼滤波器代替传统的FIR滤波器,有效提高了滤波效率。测试结果表明,该系统具有抗干扰能力强、采样精度高、处理速度快等优点。 The application of electrical capacitance tomography to high-speed devices (such as aero-engine gas path monitoring system) has been restricted by the speed of the data acquisition system. To address this problem, a novel FPGA-based capacitance data acquisition system is designed in this paper. DDR2 memory and PCI bus technology are adopted to realize high speed data transmission. Additionally, the traditional FIR filter is replaced by Kalman filter, which effectively improves the filtering efficiency. Experimental results show that the system possesses the advantages of anti-interference ability, high sampling accuracy and fast processing speed.
作者 马敏 吴海超
出处 《电子技术应用》 北大核心 2014年第1期72-74,78,共4页 Application of Electronic Technique
基金 国家自然科学基金青年科学基金项目(61102096) 天津市自然科学基金面上项目(11JCYBJC06900)
关键词 航空发动机 FPGA 数据采集 卡尔曼滤波器 DDR2 PCI aero engine FPGA data acquisition Kalman filter DRR2 PCI
  • 相关文献

参考文献9

  • 1张立峰..电容层析成像系统的设计及应用研究[D].华北电力大学,2003:
  • 2崔自强.双模态电学层析成像技术研究[D].天津:天津大学,2009. 被引量:2
  • 3孙猛,刘石,李志宏,雷兢.利用ECT对稀疏气固两相流动进行浓度测量[J].锅炉技术,2010,41(4):6-9. 被引量:2
  • 4BOLTON G T, KORCHINSKY W J, WATERFALL R C.Calibration of capacitance tomography system for liquid-liquid dispersions [JJ.Meas Sci Technol, 1998,9( 11): 1797-1800. 被引量:1
  • 5Complete 12-Bit, 40 MSPS Monolithic A/D Converter [S].1999. 被引量:1
  • 6朱惠静.PCI9054及其在高速数据采集系统中的应用[J].国外电子测量技术,2008,27(2):72-74. 被引量:9
  • 7吴建.基于FPGA的PCI数据采集卡的研究与开发[D].长沙:中南大学.2007. 被引量:1
  • 8何子述,夏威等编著..现代数字信号处理及其应用[M].北京:清华大学出版社,2009:384.
  • 9YANG W Q.Hardware design of electrical capacitance tom-ography systems [J]. Measurement Science and Technology1996,7(3):225-232. 被引量:1

二级参考文献17

  • 1Chunsheng Yan,Jing Zhong,Yanbiao Liao,et al.Design of applied optical fiber process tomography system[J].Sensors and Actuators B:Chemical,2005,104(2):324-331. 被引量:1
  • 2Yingna Zheng,Qiang Liu,Yang Li,et al.Investigation on concentration distribution and mass flow rate measurement for gravity chute conveyor by optical tomography system[J].Measurement,2006,39(7):643-654. 被引量:1
  • 3Ellis N,Briens L A,Grace J R,et al.Characterization of dynamic behavior in gas-solid turbulent fluidized bed using chaos and wavelet analyses[J].Chemical Engineering Journal,2003,96(2):105-116. 被引量:1
  • 4Ying Zheng,Qikai Zhang.Simultaneous measurement of gas and solid holdups in multiphase systems using ultrasonic technique[J].Chemical Engineering Science,2004,59(17):3505-3514. 被引量:1
  • 5Hosseini S A,Shamsai A,Ataie-Ashtiani B.Synchronous measurements of the velocity and concentration in low density turbidity currents using an Acoustic Doppler Velocimeter[J].Flow Measurement and Instrumentation,2006,17(1):59-68. 被引量:1
  • 6Yan Y,Byrne B,Coulthard J.Radiation attenuation of pulverized fuel in pneumatic conveying systems[J].Trans.Inst.Meas.Control,1993,15(2):98-103. 被引量:1
  • 7Beck M S,Williams R A.Process tomography:A European innovation and its applications[J].Meas.Sci.and Technol.,1996,7(3):215-224. 被引量:1
  • 8Dyakowski T,Luke S P,Ostrowski K L.Application of capacitance tomography to gas-solid flows[J].Chem.Eng.Sci.,1997,52(13):2099-2105. 被引量:1
  • 9Wang S,Dyakowski T,Beck M S.An application of electrical capacitance tomography to measure gas-solid motion in fluidized bed[A].Heat-transfer[C].AICHE Symposium Series,Houston,1996:156-159. 被引量:1
  • 10Yang W Q,Liu S.Electrical capacitance tomography with square sensor[J].Electronics Letters,1999,35(4):295-296. 被引量:1

共引文献9

同被引文献41

引证文献5

二级引证文献12

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部