期刊文献+

反相高效液相色谱法测定替硝唑氯化钠注射液中乙二胺四乙酸二钠含量 被引量:7

Determination of Disodium Edetate in Tinidazole and Sodium Chloride Injection by RP- HPLC
下载PDF
导出
摘要 目的建立测定替硝唑氯化钠注射液中乙二胺四乙酸二钠含量的高效液相色谱法。方法色谱柱为Agilent C18柱(150 mm×4.6 mm,5μm),流动相为乙腈-缓冲液(10%四丁基氢氧化铵溶液6 mL,加水稀释至200 mL,以磷酸调节pH至6.5)-水(20∶20∶60),检测波长为254 nm,流速为1.0 mL/min,柱温为30℃,进样量为20μL。结果乙二胺四乙酸二钠进样量在0.1~2.0μg范围内与峰面积线性关系良好(r=0.999 8),平均回收率为100.37%,RSD为0.78%(n=9)。结论该方法简便、准确、灵敏度高,重复性好,可用于替硝唑氯化钠注射液中乙二胺四乙酸二钠的含量测定。 Objective To establish the high performance liquid chromatography(HPLC)method for determining the content of disodium edetate in Tinidazole and Sodium Chloride Injection. Methods The chromatographic column was the Agilent CIs column(150 mm~ 4. 6 mm, 5 I^m) with acetonitrile -buffer solution( 10% tetrabutylammonium solution 6 mL, adding water for diluting to 200 mL, adjusting pH to 6.5 with phosphoric acid)-water(20:20:60) as the mobile phase. The detection wavelength was 254nm and the flow rate was 1.0 mL/min. The column temperature was 30 ~C. The injection volume was 20 IxL. Results The calibration curves of disodium edetate were linear in the range of 0. 1-2. 0 Ixg(r=0.999 8). The average recovery rate was 100. 37%, RSD=O. 78% (n=9). Conclusion This method is simple and accurate with high sensitivity and good reproducibility, which can be used for the content determination of disodium edetatein in Tinidazole and Soudiun Chloride Injection.
作者 陆滢
出处 《中国药业》 CAS 2013年第24期37-38,共2页 China Pharmaceuticals
关键词 高效液相色谱法 替硝唑氯化钠注射液 乙二胺四乙酸二钠 含量测定 HPLC Tinidazole and Sodium Chloride Injection disodium edentate content determination
  • 相关文献

参考文献2

二级参考文献3

  • 1ChP(中国药典).2005.Vol Ⅱ(二部):675 被引量:63
  • 2中华人民共和国国家标准GB3097-1997,海水水质标准. 被引量:2
  • 3中华人民共和国国家标准:水质镍的测定"丁二酮肟分光光度法"(GB11910-89) 被引量:1

共引文献1

同被引文献53

引证文献7

二级引证文献12

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部