期刊文献+

硅胶假体隆胸术后乳腺全数字化钼靶摄片技术探讨 被引量:2

Digital Molybdenum Target Mammography after Breast Humping by Silicone Prosthesis
下载PDF
导出
摘要 目的:探讨硅胶假体隆胸术后患者钼靶摄片的方法及技巧。方法:回顾分析46例硅胶假体隆胸术后患者的临床资料及数字钼靶片,由2位从事乳腺影像诊断的高年资医生对其图像质量进行分析,评价图像优质片率状况。结果:所有患者均能配合完成摄片,X线片解剖结构清晰,对比度及清晰度均能满足临床诊断要求,满意度为100%。结论:熟练掌握对硅胶假体隆胸术后患者钼靶摄片的方法及技巧能减少患者的不适,为临床提供高质量的钼靶片,提高诊断的准确性。 Objective To explore the methods and techniques of digital molybdenum target mammography after breast humping with the silicone prosthesis. Methods Digital molybdenum target mammography data after breast humping with the silicone prosthesis of 46 patients were analyzed retrospectively, and two senior radiologists evaluated the image equally and determine the high quality rate. Results All the examinations were completed with the cooperation of the patients, and the molybdenum target mammography, contrast and definition could meet the clinical requirements, with all the patients satisfied. Conclusion The technique of digital molybdenum target mammography after breast humping with the silicone prosthesis can make the patient comfortable and the mammograph qualified.
出处 《医疗卫生装备》 CAS 2013年第12期76-77,共2页 Chinese Medical Equipment Journal
关键词 硅胶假体隆胸术 乳腺 钼靶 X线诊断 breast humping with silicone prosthesis breast molybdenum target X-ray diagnosis
  • 相关文献

参考文献4

二级参考文献25

  • 1Buadu LD, Murakami J, Marayama S, et al. Breast lesions: correlation of contrast medium enhancement patterns on MR images with histopaphologic findings and tumor angoigenesis. Radiology, 1996,200:639-649. 被引量:1
  • 2Hulka CA, Edmister WB, Smith BL, et al. Dynamic echo-planar imaging of the breast: experience in diagnosing breast carcinoma and and correlation with tumor angoigenesis. Radiology, 1997,205: 837-842. 被引量:1
  • 3Kinkel K, Hylton MN. Challenges to interpretation of breast MRI.J Magn Reson Imaging,2001,13:821-829. 被引量:1
  • 4Malur S,Wurdinger S, Moriz A, et al. Comparision of written reports of mammography, sonography and magnetic resonance mammography for preoperative evaluation of breast lesions, with special emphasis on magnetic resonance mammography. Breast Cancer Res, 20 被引量:1
  • 5Harms SE, Flamig DP, Hesley KL, et al. MR imaging of the breast with rotating delivery of excitiation off resonance: clinical experience with pathological correlation. Radiology, 1993,187:493-501. 被引量:1
  • 6Soo MS,Kornguth PJ,Walsh R et al.Complex radial folds versus subtle signs of intracapsular rupture of breast implants: MR findings with surgical correlation. American Journal of Roentgenology . 1996 被引量:1
  • 7Brown SL,Silverman BG,Berg WA.Ruptur of silicone-gel breast implants: causes, sequelae, and diagnosis. The Lancet . 1997 被引量:1
  • 8Brody GS.On the safty of breast implants. Plastic and Reconstructive Surgery . 1997 被引量:1
  • 9Safvi A.Linguine sign. Radiology . 2000 被引量:1
  • 10Collis NC,Sharpe DT.Silicone gel -filled breast implant integrity: A retrospective review of 478 consecutively explanted implants. Plastic and Reconstructive Surgery . 2000 被引量:1

共引文献72

同被引文献22

引证文献2

二级引证文献9

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部