期刊文献+

latrogenic aortic pseudoaneurysm following anterior tho- racic spine surgery masquerading as chronic infection 被引量:1

latrogenic aortic pseudoaneurysm following anterior tho- racic spine surgery masquerading as chronic infection
原文传递
导出
摘要 Late vascular complications involving aorta are rare but devastating adversities following anterior thoracic spine operations are present.The current article describes our experience with one such patient who had an iatrogenic pseudoaneurysm of the thoracic aorta,mimicking infection.The patient was treated successfully following concomitant efforts by multidisciplinary experts with shunting.We wish to highlight upon the significance of recognizing the possible sinister consequences of a dangerously prominent spinal implant and the role of a suspicious surgeon in identifying these menacing complications at the right time.
出处 《Chinese Journal of Traumatology》 CAS CSCD 2013年第6期368-370,共3页 中华创伤杂志(英文版)
关键词 Fractures bone Aorta thoracic Aneurysm false latrogenic disease 慢性感染 主动脉 动脉瘤 假性 外科 脊柱 伪装 并发症
  • 相关文献

参考文献13

  • 1Baker JK, Reardon PR, Reardon MJ, et al. Vascular injury in anterior lumbar surgery. Spine 1993;18(5):2227-30. 被引量:1
  • 2Been HD, Kerkhoffs GM, Balm R. Endovascular graft for late iatrogenic vascular complication after anterior spinal instrumentation: a case report. Spine 2006;31 (22):E856-8. 被引量:1
  • 3Higashino K, Katoh S, Sairyo K, et al. Pseudoaneurysm of the thoracoabdominal aorta caused by a severe migration of an anterior spinal device. Spine J 2008;8(4):696-9. 被引量:1
  • 4Huitema GC, Comips EM, Castelijns MH, et al. The posi- tion of the aorta relative to the spine: is it mobile or not? Spine 2007;32(12): 1259-64. 被引量:1
  • 5Kakkos SK, Shepard AD. Delayed presentation of aortic injury by pedicle screws: report of two cases and review of the literature. J Vasc Surg 2007;47(5): 1074-82. 被引量:1
  • 6Kuklo TR, Lehman RA Jr, Lenke LG. Structures at risk following anterior instrumented spinal fusion for thoracic adoles- cent idiopathic scoliosis. J Spinal Disord Tech 2005;18(Suppl 1): 58-64. 被引量:1
  • 7Lavigne F, Mascard E, Laurian C, et al. Delayed-iatrogenic injury of the thoracic aorta by an anterior spinal instrumentation. Eur Spine J 2009;18(Suppl 2):265-8. 被引量:1
  • 8Pettiford BL, Schuchert MJ, Jeyabalan G, et al. Technical challenges and utility of anterior exposure for thoracic spine pathology. Ann Thorac Surg 2008;86(6): 1762-8. 被引量:1
  • 9McDonnell MF, Glassman SD, Dimar JR 2nd, et al. Perioperative complications of anterior procedures on the spine. J Bone Joint Surg Am 1996;78(6):839-47. 被引量:1
  • 10Minor ME, Morrissey NJ, Peress R, et al. Endovascular treatment of an iatrogenic thoracic aortic injury after spinal instrumentation: case report. J Vase Surg 2004;39(4):893-6. 被引量:1