数据中心节能技术应用探讨 被引量:6

Application Research of Data Center Energy-saving Technology
下载PDF
导出
摘要 介绍了国内数据中心的能耗现状,从空调制冷技术、机房送风与回风方式、新型不间断电源系统几个方面,对各种节能新技术进行了应用比较,分析了提高数据中心能效管理的措施,具有一定的参考价值。 The eun'ent energy consumption was intruduced, and the application of new energy-saving technologies was compared from several aspects, such as air-conditioning refrigeration technique, blowing-in and return air method of emnputer room, new type tIPS system. The measurements to impruve energy management in data cenler were analyzed. At last, this whole article was summarized, and could be referred in machine room energy-saving.
作者 杨军志
出处 《现代建筑电气》 2013年第10期38-45,61,共9页 Modern Architecture Electric
关键词 数据中心 能耗 UPS 布线 data center energy consumption uninterrupted power supply (UPS) cabling