ORC直接接触式蒸发器传热性能研究 被引量:7

Study on Heat-transfer Performance of ORC Direct Contact Evaporators
下载PDF
导出
摘要 为分析低温余热发电ORC直接接触式蒸发器内分散相在连续相中的传热性能,分别选用新型环保有机工质R245fa和THERMINOL66导热油作为分散相和连续相,进行ORC直接接触式蒸发器传热性能的研究,分析了初始传热温差、工质体积流量和导热油质量流量对ORC直接接触式蒸发器容积传热系数的影响.结果表明:容积传热系数随着传热时间的增加先呈增大趋势,然后逐渐减小并趋于平稳,但大于传热开始阶段的容积传热系数;在工质体积流量和初始传热温差为定值的情况下,为获得较大的容积传热系数,导热油质量流量应控制在较小的范围内. To analyze the heat-transfer performance of dispersed phase in continuous phase within ORC di- rect contact evaporator for low-temperature waste-heat power generation, the environmental-friendly re- frigerant R245fa and heat-transfer oil THERMINOL-R 66 were respectively taken as the dispersed phase and continuous phase, with which the influence of following factors on the volumetric heat-transfer coefficient of ORC direct contact evaporator was analyzed, such as the initial temperature difference, the refrigerant flow rate and the oil flow rate, etc. Results show that the volumetric heat-transfer coefficient rises first, drops later on, and finally tends to be stable, always being larger than the coefficient at initial period~ for a fixed refrigerant flow rate and initial temperature difference, the flow rate of heat-transfer oil should be controlled within a narrow range so as to obtain higher volumetric heat-transfer coefficient of ORC direct contact evaporators.
出处 《动力工程学报》 CAS CSCD 北大核心 2013年第12期969-973,共5页 Journal of Chinese Society of Power Engineering
基金 NFSC-云南联合基金资助项目(U0937604) 国家自然科学基金资助项目(51066002/E060701) 云南省重大产业技术开发资助专项项目(2008CD001) 云南省科技强省计划资助项目(2008KA002)
关键词 直接接触式传热 容积传热系数 有机朗肯循环 传热性能 direct contact heat transfer volumetric heat-transfer coefficient organic Rankine cycle(ORC) heat transfer performance
  • 相关文献

参考文献14

  • 1DRESCHKR U, BRUC.C;EMANN D. Fluid selectionfor the organic Rankine cycle (ORC) in biomass pow-er and heat plants [J]. Applied Thermal Engineering,2007, 27( 1 ) : 223-228. 被引量:1
  • 2王辉涛,王华.低温太阳能热力发电有机朗肯循环工质的选择[J].动力工程,2009,29(3):287-291. 被引量:38
  • 3NOMURA T, TSUBOTA M, OYA T,et al. Heatstorage in direct-contact heat exchanger with phasechange material [J]. Applied Thermal Engineering,2013, 50Cl):26-34. 被引量:1
  • 4LEMENAND T, DURANDAL C, DELLA VALLED,et al. Turbulent direct-contact heat Transfer be-tween two immiscible fluids[J]. International Journalof Thermal Sciences,2010, 49( 10) : 1886-1898. 被引量:1
  • 5SEETHARAMU K N, BATTYA P. Direct contactevaporation between two immiscible liquids in spraycolumn [J]. Journal of Heat Transfer, 1989,111(27): 780-785. 被引量:1
  • 6TRADIST L,DISC) I S, SANTINI R,et al. Vapori-zation of a liquid by direct contact in another immisci-ble liquid,Part I; vaporization of single droplet,PartII: vaporization of rising multidroplets [J ]. Interna-tional Journal of Heat and Mass Transfer, 1987, 30(9):1773-1785. 被引量:1
  • 7SIDEMAN S, GAT Y. Direct contact heat transferwith change of phase : .spray-column studies of a three-phase heat exchanger[J]. American Institute of Che-mical Engineers Journal, 1996 ,12(2) : 296-303. 被引量:1
  • 8SIQUEIROS J, BONILLA O. An experimental studyof a three-phase,direct-contact heat exchanger [J].Applied Thermal Engineering, 1999,19(5): 477-493. 被引量:1
  • 9JACOBS H R. Thermal and hydraulic design of di-rect contact spray columns for use in extracting geo-thermal brines [J]. Hemisphere, 1988 , 11 ( 52 ) : 343-369. 被引量:1
  • 10CELATA G P,CUMO M,D'ANNIBALE F. Directcontact evaporation of nearly saturated R114 in water[J]. International Journal of Heat and Mass Transfer,1995,38(8) : 1495-1504. 被引量:1

二级参考文献24

  • 1胡朋飞,崔现宝,杨志才.用于热敏物料蒸馏的直接接触传热蒸发釜的研究[J].化工进展,2002,21(z1):158-161. 被引量:4
  • 2张颖,何茂刚,贾真,刘逊.Kalina循环的热力学第一定律分析[J].动力工程,2007,27(2):218-222. 被引量:12
  • 3SALEH Bahaa, KOGI.BAUER Gerald, WEND- LAND Martin, et al. Working fluids for low-temperature organic Rankine cycles[J]. Energy, 2007,32 (7) :1210-1221. 被引量:1
  • 4HUNG T C. Waste heat recovery of organic Rankine cycle using dry fluids[J]. Energy Conversion & Management, 2001,42(5) :539-553. 被引量:1
  • 5MAGO Pedro J, CHAMRA Louay M, SRINIVA- SAN Kalyan, et al. An examination of regenerative organic Rankine cycles using dry fluids [J]. Applied Thermal Engineering, 2008,28(8/9) : 998-1107. 被引量:1
  • 6DRESCHER Ulli, BRUUGGEMANN Dieter. Fluid selection for the organic Rankine cycle (ORC)s in biomass power and heat plants [J]. Applied Thermal Engineering, 2007,27 (1) : 223-228. 被引量:1
  • 7LIUBo-Tau, CHIEN Kuo-Hsiang, WANG Chi- Chuan. Effect of working fluids on organic Rankine cycle for waste heat recovery[J]. Energy, 2004,29 (8) : 1207-1217. 被引量:1
  • 8AALTO Mika M. Correlation of liquid densities of some halogenated organic compounds[J]. Fluid Phase Equilibria, 1997,141 (1/2) : 1-14. 被引量:1
  • 9BROWN J. Steven. Predicting performance of refrigerants using the Peng-Robinson Equation of State [J]. International Journal of Refrigeration, 2007,30 (8) : 1319-1328. 被引量:1
  • 10[1]Subbaiyer S, Andhole T M, Helmer W A.ASHRAE Trans., PartⅠ,1991,97(1):118-126 被引量:1

共引文献47

同被引文献78

引证文献7

二级引证文献15

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部