摘要
总结了塘寨电厂超临界"W"火焰锅炉冷灰斗水冷壁泄漏情况,并对泄漏原因进行研究分析,为下一步研宄制定解决措施提供依据,对超临界"W"火焰锅炉的安全运行具有重要的现实意义。
This paper summarized the leakage situation of supercritical W boiler water-flame cooled hopper bottom and water wall in Tangzhai Power Plant, and studied and analyzed the cause of leakage, which provided the basis to formulate countermeasures for next research, and had important practical significance to safe operation of superefitieal W flame boiler.
出处
《贵州电力技术》
2013年第11期7-9,3,共4页
Guizhou Electric Power Technology
关键词
超临界“w”火焰锅炉
冷灰斗水冷壁
大面积泄漏
热疲劳
supercritical W flame boiler
water-cooled hopper bottom and water wall
large area leakage
thermal fatigue