期刊文献+

机械搅拌混响室独立样本数建模及实验 被引量:4

Modelling and experimental study of the number of independent samples in reverberation chamber with mechanical stirring
下载PDF
导出
摘要 混响室测试技术的精确性取决于混响室能够产生大量的独立测试样本。通过理论分析得到混响室的体积、搅拌器的尺寸以及腔体的工作频率与独立样本数的关系,推导出独立样本数的近似模型,并将实验数据与模型计算结果进行比较,对模型进行了改进和验证。结果表明:独立样本数与混响室的体积、品质因数、搅拌器的尺寸正相关,在一定范围内与搅拌器的电学尺寸负相关。该模型可以用于计算具有不同配置的不同混响室的独立样本数,具有良好的准确性和一般性。 The accuracy in reverberation chamber (RC) measurements depends on the chamber settings being able to gener-ate a large number of independent measurement samples. In this paper, an approximate theoretical model of the number of inde pendent samples is derived by theoretically analyzing how the RC configuration and the frequency influence the number of inde pendent samples, and the model is improved and verified by comparing a large amount of experimental data and calculation. The results show that the number of independent samples positively correlates with chamber volume, quality factor, and stirrer size, and negatively correlates with the electrical size of stirrers in a certain range. The model can be used to calculate the number of in dependent samples in RCs of different configurations, with good accuracy and generality.
出处 《强激光与粒子束》 EI CAS CSCD 北大核心 2013年第11期3050-3054,共5页 High Power Laser and Particle Beams
基金 国家自然科学基金青年基金项目(51107147)
关键词 混响室 独立样本 机械搅拌 自相关函数 reverberation chamber independent samples mechanical stirring autocorrelation function
  • 相关文献

参考文献12

  • 1Sorrentino A,Kildal P S,Carlberg U.Accuracy in reverberation chamber for wireless testing:Simple formulas for the number of independent samples[C]//European Conference on Antennas and Propagation.2009:2673-2677. 被引量:1
  • 2Corona P,Latmiral G,Paolini E,et al.Use of a reverberating enclosure for measurements of radiated power in the microwave range[J].IEEE Trans on Electromagnetic Compatibility,1976,18(2):54-59. 被引量:1
  • 3Hill D A.Electromagnetic theory of reverberation chambers[R].Boulder:National Institute of Standards and Technology,1998. 被引量:1
  • 4Rosengren K,Kildal P S,Carlsson C,et al.Characterization of antennas for mobile and wireless terminals by using reverberation chambers:Improved accuracy by platform stirring[J].Microwave and Optical Technology Letters,2001,30(6):391-397. 被引量:1
  • 5Lemoine C,Besnier P,Drissi M.Evaluation of frequency and mechanical stirring efficiency in a reverberation chamber[J].IEEE International Symposium on EMC,2008. 被引量:1
  • 6李爽,王建国.短脉冲激励的混响室设计[J].强激光与粒子束,2012,24(6):1439-1444. 被引量:4
  • 7Hallbj(o)rner P.A model for the number of independent samples in reverberation chambers[J].Microwave and Optical Technology Letters,2003,33(1):25-28. 被引量:1
  • 8Kostas J G,Boverie B.Statistical model for a mode-stirred chamber[J].IEEE Trans on Electromagnetic Compatibility,1991,33(4):366-370. 被引量:1
  • 9IEC 61000-4-21.Testing and measurement techniques Reverberation chamber test methods[S].2011. 被引量:1
  • 10Krauth(a)user H G,Winzerling T,Nitsch J.Statistical interpretation of autocorrelation coefficients for fields in mode-stirred chambers[J].IEEE International Symposium on EMC,2005,2:550-555. 被引量:1

二级参考文献10

  • 1Benford J, Swegle J, Schamiloglu E. High power microwaves[M]. 2nd ed. New York: CRC Press, 2007:35-37. 被引量:1
  • 2Hill D A. TN1506. Electromagnetic theory of reverberation chamber[S] National Institute of Standards and Technology (USA), 1998. 被引量:1
  • 3Corona P, Ladbury J, Latmiral G. Reverberation chamber research--then and now: a review of early work and comparison with current un-derstanding[J]. IEEE Trans on Electromagnetic Compatibility, 2002,44(1) : 87-94. 被引量:1
  • 4Crawford M I., Koepke G H. NBS-TN1092. Design, evaluation, and use of a reverberation chamber for performing electromagnetic suscep tibility/vulnerability measurements[S]. 1986. 被引量:1
  • 5Krauthauser H G, Nitsch J. Effects of the variation of the excitation and boundary conditions of mode-stirred chambers and consequences for calibration and measurements[C]// ProcofEMC Zurich 2003. 2003:615 620. 被引量:1
  • 6IEC Technical Report. IEC 61000-4-21. Electromagnetic compatibility (EMC)--Part 4-21: Testing and measurement techniques reverber- ation chamber test methods[S]. 2003. 被引量:1
  • 7Piette M, Tsigros C. IEC61000-4-21 testing: selective source-mode tuning with two orthogonal antennas scanning system[C]//IEEE Inter national Symposium on Electromagnetic Compatibility. 2008: 1-6. 被引量:1
  • 8李爽,王建国.电磁脉冲激励下混响室的场特性研究[D].西安:西北核技术研究所,2011:2225. 被引量:1
  • 9Amaut L R. Compromizing and optimizing the design of special purpose reverberation chamber[C]//IEEE International Symposium on E lectromagnetic Compatibility. 2004:237-240. 被引量:1
  • 10李爽,王建国.源搅拌对混响室场均匀性的改善[J].强激光与粒子束,2011,23(10):2724-2728. 被引量:3

共引文献3

同被引文献16

引证文献4

二级引证文献4

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部