期刊文献+

氯接触氧化过滤去除原水中锰的试验研究 被引量:4

Study on the removal of manganese from raw water by chlorine contact oxidization filtration
下载PDF
导出
摘要 采用氯接触氧化过滤去除原水中的锰,通过试验研究了除锰滤料的成熟期、投氯量及原水pH对氯接触氧化过滤除锰效果的影响。结果表明,在过滤初期,当投氯量为进水锰浓度的3倍,且原水pH达到8.7时,该方法能迅速而有效地去除原水中的锰;当滤料成熟后,只需将原水pH保持在7.3以上,并按理论投氯量投氯(进水锰浓度的1.3倍),即可获得良好的除锰效果。滤料成熟期的长短与投氯量和原水pH有关,原水pH越高,投氯量越大,滤料成熟越快。当进水锰质量浓度为1mg/L时,成熟期一般为1-15d。 Chlorine contact oxidation filtration process has been used for removing manganese from raw water. Through tests, the effects of the maturity of manganese-removing filter, chlorine dosage and pH on the removing efficiency of manganese by chlorine contact oxidation filtration are investigated. The results show that when chlorine dosage is 3 times of the manganese concentration in influent and pH is 8.7 in the initial filtration stage, manganese in influent can be removed rapidly and effectively. After the filtration media get mature, it is necessary only to keep the pH of raw water at above 7.3, and add chlorine according to theoretical chlorine dosage ( 1.3 times of manganese con- centration in influent). As a result,good manganese-removing efficiency can be obtained. The length of the filter maturity is related to the dosage of chlorine and pH of raw water. The higher pH is, the more chlorine dosage and the shorter the filter maturity. When the manganese mass concentration in influent is 1 mg/L, the maturity is usually 1- 15d.
出处 《工业水处理》 CAS CSCD 北大核心 2013年第10期23-26,共4页 Industrial Water Treatment
基金 水体污染控制与治理科技重大专项(2009ZX07423-004)
关键词 原水 除锰 过滤 氯接触氧化 应急处理 raw water removal of manganese filtration contact oxidation of chlorine emergency treatment
  • 相关文献

参考文献10

二级参考文献39

共引文献160

同被引文献81

  • 1赵弢,高志奎,徐广辉,王梅,高荣孚.非调制式荧光仪测定叶绿素荧光参数的研究[J].生物物理学报,2006,22(1):34-38. 被引量:13
  • 2张玲,叶正钱,李廷强,杨肖娥.铅锌矿区污染土壤微生物活性研究[J].水土保持学报,2006,20(3):136-140. 被引量:26
  • 3Liu J, Zhang H L, You K, et al. Different filter material on the north- east biological iron manganese removal effect of groundwater in the countryside [J].Applied Mechanics and Materials,2014,522: 465-468. 被引量:1
  • 4Abdul Kadir A, Othman N, M AzmiN A. Potential of Using ROSA centifolia to remove iron and manganese in Groundwater Treatment [J].Intemational Journal of Sustainable Construction Engineering and Tectmology,2012,3(2):70-82. 被引量:1
  • 5Das B, Hazarika P, Saikia G, et al. Removal of iron from groundwa- ter by ash: A systematic study of a traditional method[J].Joumal of Hazardous Materials,2007,141 (3): 834-841. 被引量:1
  • 6bin Jusoh A, Cheng W H, Low W M, et al. Study on the removal of iron and manganese in groundwater by granular activated carbon[J]. Desalination,2005,182(1):347-353. 被引量:1
  • 7Wang Y, Sikora S, Kim H, et al. Effects of solution chemistry on the removal reaction between calcium carbonate-based materials and Fe (lI)[J].Science of the Total Environment,2013,443:717-724. 被引量:1
  • 8Valentukeviien6 M. Experimental research on removal of iron and ammonium ions from groundwater by natural silica sand [J]. Geologija,2008,50(3). 被引量:1
  • 9Li X, Chu Z, Liu Y, et al. Molecular characterization of microbial populations in full-scale biofilters treating iron, manganese and am- monia containing groundwater in Harbin, China [J].Bioresource Technology,2013,147:234-239. 被引量:1
  • 10Fu J X, Shang J, Zhao Y H. Simultaneous removal of iron, man- ganese and ammonia from groundwater in single biofilter layer us- ing BAF[J].Advanced Materials Research,2011,183:442-446. 被引量:1

引证文献4

二级引证文献25

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部