摘要
针对深圳市下坪垃圾填埋场排放渗滤液管道结垢现象 ,从结垢物组成、水质情况、管道设计、管道使用方法等多方面 ,就其结垢原因进行了分析探讨 ,并提出了解决办法及防治对策。
The scale build up on the refuse leachate drainage pipe in Xiaping Refuse Land filling Yard in Shenzhen city was observed. The causes of scaling were examined and researched by different ways including the analysis of scaling substances, the composition examination of the leacahte liquid and observation of the design and operation of the pipeline. The countermeasures of the protection have been proposed.
出处
《给水排水》
CSCD
北大核心
2000年第12期29-31,共3页
Water & Wastewater Engineering