摘要
介绍了焦化废水生物脱氮处理系统开工调试中污泥培养驯化、系统稳定运行改善出水水质 ,以及影响硝化和反硝化反应的因素等几方面的体会。
The early stage works that the author participated to start up a biological denitrification facility treating coking wastewater including sludge adaptation, system performance stabilization and effluent improvement are presented in this paper. Also the influence factors on the nitrification and denitrification are investigated.