叙述超声旋涡流量计利用旋涡调制连续超声波的原理,旋涡调制连续超声波有调频和调幅,这两种调制同时存在,时而相互加强,时而相互减弱,因而产生不稳定性。着重介绍产生不稳定性的原因以及解决方法。
The principle of ultrasonic vortex flowmeter is described. The continuous ultrasonic wave is modulated by vortex flow. The modulation includes both frequency modulation and amplitude modu-lation which are interacted. Thus the unstability is induced because of the increment and decrement on modulation from interaction.The causes of formation on unstability and the solutions are emphasized.