期刊文献+

两个水景剧院的建声设计与音质模拟 被引量:2

Architectural acoustical design and acoustic simulation of two waterscape opera houses
下载PDF
导出
摘要 概述了建于远香湖湖畔的上海嘉定保利大剧院和建于小东海与鹿回头湾交汇处的三亚半岛音乐厅两个水景剧院的建筑概况,重点介绍了保利剧院1500座歌剧厅和半岛音乐厅1300座歌剧厅的音质设计思想、技术指标及建声措施,并对两个水景剧场进行了厅堂音质计算机模拟分析,同时还完成了保利1500座歌剧厅1:10声学缩尺模型试验,最后依据计算机空满场模拟结果对两个剧场的音质进行了初步评估。 An overview on the architectural design of two waterscape theaters is summarized. One named Jiading Poly grand theater built beside Yuanxiang Lake in Shanghai and the other named Sanya Serenity Coast concert hall built on the intersection of small East China Sea and Luhuitou Bay. The main ideas and specifications of acoustics design on 1500-seats opera house in Poly Grand Theater and 1300-seats opera house in Sanya Serenity Coast concert hall are in- troduced in detail, and so are the approaches to making satisfied acoustics. Then acoustics simulation analysis was done in both opera houses with Odeon which is the room acoustics program. Meanwhile, 1/10 scale-model test of 1500-seats opera house was done. Preliminary acoustics evaluations on those two waterscape grand theaters based on computer simulations are given.
出处 《声学技术》 CSCD 2013年第4期312-316,共5页 Technical Acoustics
关键词 歌剧厅 音质计算机模拟 缩尺模型试验 音质评价 opera house acoustic simulation scale-model test acoustic evaluation
  • 相关文献

参考文献5

二级参考文献4

共引文献16

同被引文献23

  • 1燕翔.剧场建筑声学的发展[J].建筑技艺,2012(4):58-63. 被引量:5
  • 2王峥,陈金京.厅堂音质缩尺模型在声学设计中的应用[J].演艺设备与科技,2007(1):35-42. 被引量:2
  • 3JJF1143-2006,混响室声学特性校准规范[S]. 被引量:3
  • 4GB/T50412-2007,厅堂音质模型试验规范[s]. 被引量:2
  • 5Hegvold L W. A 1 : 8 scale model auditor [ J ]. Applied Acoustics, 1971,4(4) :237-256. 被引量:1
  • 6橘秀樹,石井聖光.音響模型実験のための内装材?吸音特性のシミュレーション[J].日本音響撃舎誌,1972 ,28(4) : 169-175. 被引量:1
  • 7Nascimento R L,Zindeluk M. Scaled absorption materials for scale modeling [ C ] // INTER-NOISE and NOISE- CON Congress and Conference Proceedings. Rio de Janei- ro : Institute of Noise Control Engineering, 2005 : 2204- 2208. 被引量:1
  • 8Jeon J Y, Ryu J K, Kim Y H, et al. Influence of absorption properties of materials on the accuracy of simulated acoustical measures in 1:10 scale model test [ J ]. Applied Acoustics, 2009,70 ( 4 ) : 615 - 625. 被引量:1
  • 9Choi Y,Lee J,Joo H,et al. Effect of sample size on mea- surement of the absorption by seats [ J ]. Building Acous- tics,2011,18( 1 ) :83-96. 被引量:1
  • 10Jang H S, Jeon J Y. Evaluation of the absorption by the orchestra in concert halls using scale model and computer simulation [ C]//International Symposium on Room Acous- tics. Toronto: [ s. n. ] ,2013. 被引量:1

引证文献2

二级引证文献2

相关作者