期刊文献+

HFETR试验回路稳压器水位测量 被引量:4

Water-Level Measurement for Pressurizer of HFETR Test Loop
下载PDF
导出
摘要 在高温高压容器中采用差压式水位计测量水位的方法,通常由于容器中介质密度的变化给测量带来很大误差。为了提高高通量工程试验堆 (HFETR)试验回路稳压器水位测量精度,本文将介质密度随压力变化的函数关系输入测量仪表中,使稳压器的水位测量实现了介质密度的自动补偿。经试验标定和系统运行证明,此测量系统具有稳定性好、测量精度高和补偿范围大等特点。 When a differential pressure water- level gauge is used to measure the water- level in the vessel,large uncertainty can be induced because of the change of media density in the vessel.In order to raise the precision of water- level measurement for pressurizer of High- Flux Engineering Test Reactor (HFETR) Test loop,the auto- compensation of the density has been realized in the measurement of water- level through putting the functions that the density changes with the pressure into the measuring meter.Experiment and operation have confirmed that the system has the properties of the stability,high precision,large range of compensation,etc.
出处 《核动力工程》 EI CAS CSCD 北大核心 2000年第6期541-545,共5页 Nuclear Power Engineering
关键词 高通量工程试验堆 试验回路 稳压器 水位测量 自动补偿 High-Flux engineering test reactor Test loop Pressurizer Water-level measurement Auto-compensation
  • 相关文献

同被引文献20

引证文献4

二级引证文献4

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部