摘要 天津国贸中心为天津小白楼地区标志性建筑之一,A塔楼高250m,共60层,为烂尾楼加固改造工程,是我国首次采用套索形式连接阻尼器的高层钢结构建筑之一。阐述了目前结构耗能减振的研究及发展现状,给出天津国贸中心A塔楼的结构特点,介绍A塔楼阻尼器的楼层布置及所采用的支撑类型。计算表明,设置少量按套索安装的非线性黏滞阻尼器后,天津国贸中心A塔楼的风振加速度降低,A塔楼的抗震性能得到了改善。采用近似方法得到了本工程设置黏滞阻尼器后的附加阻尼比。 Tianjin International Trade Centre, residential flats have reinforced renovation project, is one of the dominant high-rise structures in the "Xiaobailou" district of Tianjin. The tower A with 60 story and 250 meters high is the first in China to adopt the toggle-connected damper. This article briefly introduces the research and the development of the liquid viscous dampers by way of describing the structural characters of Tianjin International Trade Centre tower A, and recommends the layout of the dampers as well as gives the damper connection configuration adopted in this building.The calculation show that small number of dampers can successfully reduce the acceleration caused by the wind vibration, and also improve aseismatic performance. The paper gives an additional damping ratio of the project with viscous dampers with approximate method.
作者 彭程 陈永祁
出处 《钢结构》 2013年第7期54-59,共6页 Steel Construction
关键词 黏滞阻尼器 加速度 套索 fluid viscous damper acceleration toggle
  • 相关文献

参考文献8

二级参考文献41

  • 1吴耀辉,李爱群,张志强,黄镇,娄宇,李培彬,赵广鹏.银泰中心主塔楼方案的抗震分析[J].建筑结构,2004,34(7):3-6. 被引量:7
  • 2魏琏,郑久建.用规范反应谱计算减震结构的探讨[J].建筑结构,2004,34(10):17-20. 被引量:13
  • 3JGJ99-1998,高层民用建筑钢结构技术规程[S].北京:中国建筑工业出版社,1998. 被引量:17
  • 4陈永祁.Taylor粘滞阻尼器性能试验报告[R].哈尔滨:哈尔滨工业大学力学与结构实验中心. 被引量:1
  • 5OSCAR M RAMIREZ, M C CONSTANTINOU, C A KIRCHER, et al. Development and evaluation of simplified procedures for analysis and design of buildings with passive energy dissipation systems [ R ]. 2000. 被引量:1
  • 6NEHRP Guidelines for the Seismic Rehabilitation of Buildings [ M ]. FEMA Publication 273, Prepared for the Building Seismic Safety Council Washington, D.C. 被引量:1
  • 72000 Edition NEHRP recommended provisions for seismic regulations for new buildings and other structures Provisions (FEMA 368 ) Prepared for the Building Seismic Safety Council Washington, D.C. 被引量:1
  • 8SOONG T T, DARGUSH G F. Passive Energy Dissipation Systems in Structural Engineering[ M]. John Weley & Sons, 1997. 被引量:1
  • 9刘季.结构抗震抗风振动控制[C]//第六届结构工程学术会议,1997:1.20. 被引量:2
  • 10SELEEMAH A A, CONSTANTINOU M C. Investigation of seismic response of buildings with linear and nonlinear fluid viscous dampers [R]. NCEER Report-97-0007, National Center for Earthquake Engineering Research, University at Buffalo, State University of New York, Buffalo, NY. 被引量:1

共引文献1249

同被引文献176

引证文献18

二级引证文献144

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部