期刊文献+

28000m^3/h空分装置试车及冷备操作总结

Commissioning of 28000 m3/h Air Separator and Cold State Operation Summarization
下载PDF
导出
摘要 简述了大唐公司28000 m3/h空分装置在试车过程中出现的问题,有上塔安全阀泄漏、液氮泵出口安全阀泄漏导致主冷液面降低、空冷塔和水冷塔液位测量不准及液氮泵密封气管路的改造。同时也描述了空分装置在冷备时需注意的问题和冷备时快速启动的方法。 The problems troduced briefly. The problems in commissioning of Datang's 28000 m3/h air separator are in include leakage of the up tower safety valve, leakage of liquid nitrogen pump outlet safety that causes decrease of the main condenser liquid level, inaccurate measurement of air cooling tower and water cooling tower liquid level. The reconstruction pro ject of liquid nitrogen pump that should be paid attention starting method for cold state sealing gas pipeline is presented. At the same time, the problems to in cold state preparation for the air separator and the quick preparation of the air separator are also described.
出处 《冶金动力》 2013年第8期30-33,共4页 Metallurgical Power
关键词 安全阀 液氮泵 泄漏 液位 密封气 冷备 冷启动 safety valve liquid nitrogen pump leakage liquid level sealing gas cold state preparation cold starting