摘要
某型炮射导弹在定型试验期间出现瞄准线跳动、工作指示灯反复熄灭、目标丢失的现象,致使炮射导弹无法正常工作。造成制导火控系统工况转换的原因较多,为了快速查明该故障原因,利用模糊综合评判方法,较为准确地实现故障定位,通过后续试验数据结果证明,该方法有效可靠,对炮射导弹定型试验期间故障诊断具有积极的参考价值。
A gun launched missile appeared such phenomena during the approval test as follows: aim line pulsated,aim lost and indicator light blacked out again and again,the gun launched missile can not work normally.There are many reasons that make the work condition of the guidance fire control system changed,in order to find out the fault.It can make use of fuzzy comprehensive to find out the fault causation.According to later testing data,this method has availability and credibility,and it also has some value for fault diagnosis of gun launched missile during approval test.
出处
《火力与指挥控制》
CSCD
北大核心
2013年第7期11-12,15,共3页
Fire Control & Command Control
基金
军队重点试验基金资助项目(装[2011]20110728)
关键词
炮射导弹
定型试验
模糊综合评判
gun launched missile
approval test
fuzzy comprehensive