期刊文献+

电磁导航辅助全膝关节置换术的早期临床结果 被引量:4

Early clinical results of electromagnetic navigation assisted total knee arthroplasty
原文传递
导出
摘要 目的回顾性评价电磁导航辅助全膝关节置换(totalkneearthroplasty,TKA)术后假体植入和重建下肢力线的准确性,探讨应用电磁导航系统施行全膝关节置换术的技术特点和早期临床疗效。方法对2006年7月至2007年2月电磁导航辅助初次TKA的初始连续病例64例100膝进行回顾性研究,男7例,女57例;年龄57~79岁,平均66.9岁。术后观察导航时间,止血带时间、出血量和48h引流量。x线评估包括测量术前和术后3个月下肢机械轴线角,股骨、胫骨假体的冠状面倾斜角(α角和β角γ和股骨假体矢状面倾斜角(γ角)。内翻表示为“+”,外翻表示为“-”。观察手术前、术后3个月的KSS评分膝关节功能、膝关节屈伸活动度(rangesofmotion,ROM)和并发症。结果导航时间为(10±2)min/膝,止血带时间为(93±9)min。48h出血量、引流量为(483±55)ml。手术前后机械轴线角分别为(+8.07±6.69)°,(+1.20±1.92)°,两者差异有统计学意义(P〈0.05)。术后α角为(89.33±1.64)°,β角为(89.64±1.47)°,γ角为(90.86±2.37)°,术前和术后3个月KSS评分分别为(86±18)分和(137±26)分,两者差异有统计学意义(P〈0.05)。术前和术后3个月ROM分别为(92±21)°和(108±24)°,差异有统计学意义(P〈0.05)。术后下肢机械轴线、α角、β角和γ,角与术后KSS评分、ROM间的相关性均无统计学意义(P〉0.05)。术后无感染、血管神经损伤、骨折、下肢深静脉血栓形成等并发症发生。结论电磁导航系统是安全可靠的,应用该系统行TKA可获得理想的假体位置和下肢力线,以及早期优良的临床疗效。 Objective To retrospectively evaluate the accuracy of postoperative prosthesis implantation and reconstruction of lower limb alignment after total knee arthroplasty ( TKA ) using an electromagnetic ( EM ) navigation system, and to investigate the technical characteristics and early clinical results of EM navigation assisted TKA. Methods The data of 64 initial consecutive patients ( 100 knees ) who underwent primary TKA using an EM navigation system from July 2006 to February 2007 were retrospectively studied. There were 7 males and 57 females, whose mean age was 66.9 years old ( range; 57-79 years ). The navigation time, tourniquet time, blood loss and drainage flow in 48h were observed after the operation. The mechanical axis angle of the lower extremity, the coronal inclination angle of femoral and tibial prostheses and the sagittal inclination angle of femoral prostheses ( α, βand γ angles ) were measured based on X-rays before the operation and at the 3rd month after the operation. Varus was expressed as positive ( ± ) and valgus negative ( - ). The knee function was evaluated using the Knee Society Score ( KSS ) before the operation and at the 3rd month after the operation, and the knee joint flexion and extension range of motion ( ROM ) and complications were also recorded. Results The navigation time was ( 10±2 ) min for each knee, and the tourniquet time was ( 93±9 ) min. The blood loss and drainage flow in 48 h were ( 483±55 ) ml. The preoperative and postoperative mechanical axis angles were ( ±8.07±6.69 ) ° and ( ±1.20±1.92 ) ° respectively, and statistically significant differences were found between them ( P〈0.05 ). The postoperative α angle, β angle and γ angle were ( 89.3±1.64 ) °, ( 89.64±1.47 ) ° and ( 90.86±2.37 ) ° respectively. The KSS scores were ( 86±18 ) points and ( 137±26 ) points respectively before the operation and at the 3rd month after the operation, and statistically significant
出处 《中国骨与关节杂志》 CAS 2013年第7期396-401,共6页 Chinese Journal of Bone and Joint
关键词 关节成形术 置换 外科手术 计算机辅助 电磁辐射 外科手术 膝关节 Arthroplasty, replacement Surgery, procedures, operative Knee joint computer-assisted Electromagnetic radiation Surgical
  • 相关文献

参考文献19

  • 1Jeffery RS,Morris RW,Denham RA. Coronal alignment after total knee replacement[J].{H}JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME,1991,(05):709-714. 被引量:1
  • 2Rand JA,Coventry MB. Ten-year evaluation of geometric total knee arthroplasty[J].{H}Clinical Orthopaedics and Related Research,1988.168-173. 被引量:1
  • 3Mason JB,Fehring TK,Estok R. Meta-analysis of alignment outcomes in computer-assisted total knee arthroplasty surgery[J].{H}Journal of Arthroplasty,2007,(08):1097-1106. 被引量:1
  • 4Hernández-Vaquero D,Suarez-Vazquez A,Sandoval-Garcia MA. Computer assistance increases precision of component placement in total knee arthroplasty with articular deformity[J].{H}Clinical Orthopaedics and Related Research,2010,(05):1237-1241. 被引量:1
  • 5Kim YH,Park JW,Kim JS. Computer-Navigated Versus Conventional Total Knee Arthroplasty[J].{H}Journal of Bone and Joint Surgery-American Volume,2012,(22):2017-2024. 被引量:1
  • 6Zhang GQ,Chen JY,Chai W. Comparison between computer-assisted-navigation and conventional total knee arthroplasties in patients undergoing simultaneous bilateral procedures:a randomized clinical trial[J].{H}Journal of Bone and Joint Surgery-American Volume,2011,(13):1190-1196. 被引量:1
  • 7Jung KA,Lee SC,Ahn NK. Delayed femoral fracture through a tracker pin site after navigated total knee arthroplasty[J].{H}Journal of Arthroplasty,2011,(03):505.e9-505ell. 被引量:1
  • 8Tigani D,Busacca M,Moio A. Preliminary experience with electromagnetic navigation system in TKA[J].{H}KNEE,2009,(01):33-38. 被引量:1
  • 9Smith JR,Rowe PJ,Blyth M. The effect of electro-magnetic navigation in total knee arthroplasty on knee kinematics during functional activities using flexible electrogoniometry[J].{H}Clin Biomech(Bristol Avon),2013,(01):23-28. 被引量:1
  • 10Kellgren JH,Lawrence JS. Radiological assessment of osteoarthrosis[J].{H}ANNALS OF THE RHEUMATIC DISEASES,1957,(04):494-502. 被引量:1

二级参考文献29

  • 1张先龙,邵俊杰,王琦,沈灏,蒋垚.计算机导航辅助下微创人工全膝关节置换的初步经验[J].中华骨科杂志,2006,26(10):654-660. 被引量:14
  • 2Mielke RK, Clemens U, Jens JH, et al. Navigation in knee endoprosthesis implantation: preliminary experiences and prospective comparative study with conventional implantation technique. Z Orthop Ihre Grenzgeb, 2001,139:109 被引量:1
  • 3Decking R, Markmann Y, Fuchs J, et al. Leg axis after computer-navigated total knee arthroplasty: a prospective randomized trial comparing navigated and manual implantation. J Arthroplasty,2005,20:282 被引量:1
  • 4Hart R, Janecek M, Chaker A, et al. Total knee arthroplasty implanted with and without kinematic navigation.Int Orthop ,2003,27:366 被引量:1
  • 5Lotke PA, Ecker ML. Influence of positioning of prosthesisin total knee replacement. J Bone Joint Surg (Am), 1977,59:77 被引量:1
  • 6Mihalko WM, Duquin T, Axelrod JR ,et al. Effect of one- and two-pin reference anchoring systems on marker stability during total knee arthroplasty computer navigation. Comput Aided Surg, 2006, 11:93 被引量:1
  • 7Hart R. Total knee arthroplasty implanted with and without kinematic navigation International Orthopaedics (SICOT), 2003,27:366 被引量:1
  • 8Hollister AM, Jatana S, Singh AK. The axes of rotation of the knee. Clin Orthop, 1993,290:259 被引量:1
  • 9Jerosch J, Peuker E, Philipps B, et al.Interindividual reproducibility in perioperative rotational alignement of femoral components in knee prosthetic surgery using the transepicondylar axis. Knee Surg Sports Traumatol Arthrosc, 2002,10 : 194 被引量:1
  • 10Stulberg SD, Loan P, Satin V. Computer-assisted navigation in total knee replacement: results of an initial experience in thirty-five patients. J Bone Joint Surg(Am), 2002,84:90 被引量:1

共引文献10

同被引文献31

引证文献4

二级引证文献27

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部