期刊文献+

不同X线方法计算髋臼杯前倾角的准确性和可靠性研究 被引量:8

Accuracy and reliability of different methods to evaluate the cup anteversion by radiographic calculation
原文传递
导出
摘要 [目的]本文研究了文献上7种X线片测量髋臼前倾角的可靠性和准确性,以总结出适合临床应用的测量方法。[方法]对2011年9月20日~10月20在积水潭医院矫形骨科进行初次全髋关节置换的60个病人60例髋关节进行了CT和X线片测量髋臼假体前倾角研究。以CT测量结果为金标准,三位独立的测量者使用7种X线测量方法测量的前倾角结果与CT测量的结果进行了比较以评估各种方法的准确性,并评估了各种测量方法的组内和组间测量的可靠性。[结果]所有7种X线测量方法均有很高的组内和组间测量可靠性。与CT测量结果相比较,Widmer方法和Visser方法是不准确的,其他方法均是准确的。Visser方法与解剖学前倾角有正向强相关性。[结论]7种X线测量髋臼假体前倾角的方法中Lewinneck、Hassan、Ackland、Liaw、和Pradhan方法是可靠和准确的,Wid-mer方法和Visser方法是不准确的,但Visser方法可以用于测量髋臼假体的解剖学前倾角。考虑到测量的准确和计算的简便性,建议临床上采用Lewinneck方法和Liaw方法测量髋臼假体的前倾角。 [ Objective] The aim of this study was to evaluate the accuracy and reliability of seven methods those are repor- ted in literature and to suggest a precise and convenient method for clinical use. [ Method] In 60 consecutive patients with 60 THAs performed between September 20th to October 20th 2011 in our hospital, both CT scan and plain anteroposterior plain radi- graphs were taken. Anteversion of the acetabular component was measured by three independent examiners on plain radiographs using these seven methods. Measurements using 3D CT were used as the gold standard reference to assess the validity of the seven methods. The intra-and interobserver reliabilities of each measurement were also evaluated. [ Result] All measurements on plain anteroposterior radiographs had excellent intra-and interobserver reliability. Measurements made using the methods of Widmer and of Visser were significantly different from the 3D CT measurements ( both P 〈 0. 001 ) , whereas measurements made using the remaining five methods were similar to the CT measurements. Whereas measurements using the method of Visser were strongly correlated with the anatomical anteversion measured on 3 D CT. [ Conclusion ] The methods of Lewinneck, Has- san, Ackland, Liaw and Pradhan are reliable and accurate, whereas the methods of Widmer and Visser are not accurate. But the method of Visser can be used to measure anatomical anteversion on plain anteroposterior radiographs. With regard to validity and convenience for calculation, we recommend the use of the method described by Lewinnek and Liaw for measurement of an- reversion of the acetabular component.
出处 《中国矫形外科杂志》 CAS CSCD 北大核心 2013年第14期1427-1434,共8页 Orthopedic Journal of China
关键词 髋关节置换 前倾角 X线片 hip arthroplasty, :anteversion, plain radiograph
  • 相关文献

参考文献20

  • 1Barrack RL, Lavernia C, PLies M, et al. Virtual reality computer ani- mation of the effect of component position and design on stability after total hip arthroplasty [ J ]. Orthop Clin North Am,2001,32:569. 被引量:1
  • 2翟吉良,蔡思毅,翁习生.人工全髋关节置换术后脱位原因分析[J].中国矫形外科杂志,2013,21(1):58-60. 被引量:28
  • 3Kennedy JG, Rogers WB, Soffe KE, et al. Effect of acetabular com- ponent orientation on recurrent dislocation, pelvic osteolysis, poly- ethylene wear, and component migration [ J ]. J Arthroplasty, 1998,5:530 - 534. 被引量:1
  • 4Lin F. Validation of a computer navigation system and a CT method for determination of the orientation of implanted aeetabular cup in to- tal hip arthroplasty : a cadaver study [ J ]. Clin Biom,2008,23 : 1004 -1011. 被引量:1
  • 5Lewinnek GE, Lewis JL, Tarr R,et al. Dislocations after total hip - replacement arthroplasties [ J ]. J Bone Joint Surg Am, 1978, 60: 217. 被引量:1
  • 6Hassan DM, Johnston GH, Dust WN,et al. Radiographic calculation of anteversion in acetabular prostheses [ J ]. J Arthroplasty, 1995,10 : 369 - 372. 被引量:1
  • 7Liaw CK, Hou SM, Yang RS,et al. A new tool for measuring cup o- rlentation in total hip arthroplasties from plain radiographs [ J ]. Clin Orthop,2006,451 : 134 - 139. 被引量:1
  • 8Ackland MK, Bourne WB, Uhthoff HK. Anteversion of the acetabu- lar cup : measurement of angle after total hip replacement[ J]. J Bone Joint Surg Br, 1986,68:409 - 413. 被引量:1
  • 9Murray DW. The definition and measurement of acetabular orienta- tion[J]. J Bone Joint Surg Br,1993,75:228. 被引量:1
  • 10Widmer KH. A simplified method to determine acetabular cup ante- version from plain radiographs[ J ]. J Arthroplasty, 2004,19 : 387 - 390. 被引量:1

二级参考文献27

  • 1裴福兴,杨静.全髋关节置换术后脱位的防治[J].继续医学教育,2006,20(12):48-50. 被引量:1
  • 2高军胜,曲彦隆,武志超,周继辉,李宗虎.全髋关节置换术后脱位的研究进展[J].中国矫形外科杂志,2007,15(16):1233-1234. 被引量:11
  • 3Morrey BF. Instability after total hip arthroplasty[J].Orthopedic Clinics of North America,1992.237-248. 被引量:1
  • 4Woo RYG,Morrey BF. Dislocation after total hip arthroplasty[J].Journal of Bone and Joint Surgery-American Volume,1982.1295-1306. 被引量:1
  • 5Demos HA,Rorabeck CH,Bourne RB. Instability in primary total hip arthroplasty with the direct lateral approach[J].Clinical Orthopaedics,2001.168-180. 被引量:1
  • 6Dorr LD,Wan Z. Causes of and treatment protocol for instability of total hip replacement[J].Clinical Orthopaedics,1998.144-151. 被引量:1
  • 7Levy BA,Berry DJ,Pagnano MW. Long-term survivorship of cemented all-polyethylene acetabular components in patients 》 75years of age[J].Journal of Arthroplasty,2000.461-467. 被引量:1
  • 8Morrey BF. Difficult complications after hip joint replacement:dislocation[J].Clinical Orthopaedics,1997.179-187. 被引量:1
  • 9Hedlundh U,Ahnfelt L,Hybbinette CH. Dislocations and the femoral head size in primary total hip arthroplasty[J].Clinl Orthop,1996.226-233. 被引量:1
  • 10Ekelund A,Rydell N,Nilsson OS. Total hip arthroplasty in patients 80 years of age and older[J].Clinical Orthopaedics,1992.101-106. 被引量:1

共引文献27

同被引文献81

  • 1杨军林,肖学军,彭成宏,吴锡炳,周倩静,王永胜,李宁,王维,费志军,李佛保.单张X线片法与CT法测量股骨颈前倾角的比较[J].中华创伤骨科杂志,2004,6(12):1356-1357. 被引量:14
  • 2Widmer KH,Zurfouh B. Compliant positioning of total hip com- ponents for optimal range of motion[J]. J Orthp Res ,2004,22 (4) : 815-821. 被引量:1
  • 3Parvizi J, Picinic E, Sharlcey PF. Revision total hip arthroplasty for instability:surgical technique and principles[J]. J Bone Joint Surg Am, 2008,90(5) : 1134-1142. 被引量:1
  • 4Biedermann R ,Tonin A ,Krismer M ,et al. Reducing the risk of dislocation after total hip arthroplasty : the effect of orientation of acetabular component[J]. J Bone Joint Surg Br,2005,87 (6):762- 769. 被引量:1
  • 5Lewinnek GE, Lewis JL, Tart R, et al. Dislocations after total hip- replacement arthroplasties[J]. J Bone Joint Surg Am, 1978,60 (2) : 217-220. 被引量:1
  • 6Kalteis T, Handel M, Bathis H, et al. Imageless navigation for in- sertion of the acetabular component in total hip arthroplasty : is it as accurate as CT-based navigation? [J]. J Bone Joint Surg Am, 2006,88(2):163-167. 被引量:1
  • 7Dorr LD, Malik A, Dastane M, et al. Combined anteversion teeh-nique for total hip arthroplasty[J]. Clin Orhop Relat Res,2009, 467(1) :119-127. 被引量:1
  • 8Miki H, Kyo T, Sugano N. Anatomical hip range of motion after implantation euring total hip arthroplasty with a large change in pelvic inclination[J]. J Arthroplasty, 2012,27 (9) : 1641-1650. 被引量:1
  • 9Inaba Y, Dorr L, Wan Z, et al. Operative and patient care tech- niques for posterior mini-incision total hip arthroplasty[J]. Clin Orhop Relat Res ,2005,441 : 104-114. 被引量:1
  • 10Lin F. Validation of a computer navigation system and a CT method for determination of the orientation of implanted acetabular cup in total hip arthroplasty:a cadaver study[J]. Clin Biomech (Bristol, Avon) ,2008,23 (8) : 1004-1011. 被引量:1

引证文献8

二级引证文献48

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部