摘要
目的研究ICL(Implantable contact lens,ICL)晶状体的距离以及虹膜张力在ICL并发白内障中的意义。方法临床病例对照研究。对2006年8月至2012年8月在深圳市眼科医院就诊患者,采用眼前段全景OCT观察并发白内障患者ICL在后房的位置变化,并采用Independent-Samples T Test与无并发白内障的患者进行比较。结果瞳孔散大后,ICL并发白内障患者的ICL周边部距晶状体前表面最小间距(D3值)为(77.75±8.70)μm,变化范围69.05~86.45μm;ICL合并正常晶状体患者的D3值为(145.68±28.88)μm,变化范围116.8-174.56μm,二者进行Independent-Samples T Test,P=0.001〈0.05,差异有统计学意义。ICL并发白内障患者D2-D1值(虹膜张力差)为(321±21.31)μm,变化范围299.69-342.31μm;ICL术后透明晶状体患者的D2-D1值为(286.32±60.46)μm,变化范围225.86-346.78μm,P=0.03〈0.05,差异有统计学意义。结论ICL周边部距晶状体前表面的最小间距(D3值)和虹膜张力差(D2-D1值)在并发性白内障的发病机制中具有重要作用。D3值大于116.8μm是相对安全的间距,发生并发性白内障的几率较小;当D3小于86.45μm和D2-D1值大于299.69μm时,并发性白内障的几率增大。
Objective To study the significance of the distances from ICL to lens and iris ten- sion in complicated cataract of ICL. Methods Based on the position changes of ICL in the posteri- or chamber with complicated cataract patients and with no complicated cataract patients with anterior segment and full-field optical coherence tomography, the data of the two group were analysed with the Independent-samples T Test. Results Under mydriasis, the average minimum distance between ICL peripheral part and the front surface of lens (D3 value) in study group was (77,75 ± 8.70)μm, ranged from 69.05 to 86.45μm, and (145.68±28.88)μm, ranged from 116.8 to 174.56μm in control group. The Independent-samples T Test showed the highly significant difference statistically between them (P =0.03〈0.05); The iris tension differential (D2-Dlvalue) was respectively (321±21.31)μm(range 299.69 to 342.315μm) and (286.32±60.46)μm (range 225.86 to 346.78μm) in study group and control group. A statistical comparison between the two groups is significant with regard to iris tension (P =0.03〈0.05) . Conclusions The minimum distance between the peripheral part of ICL and the front surface of lens (D3 value) and the iris tension (D2-D1 value) is of great significance in the etiology of complicated cataract after ICL implant. D3 value of more than l16.8μm is relative- ly safe and not easy to cause lens opacity. But D3 value less than 86.45μm and D2-D1 value more than 299.69μm would increase the chance of contact between the ICL and the lens and then the oc- currence of post-operative cataract.
出处
《中国实用眼科杂志》
CSCD
北大核心
2013年第6期684-687,共4页
Chinese Journal of Practical Ophthalmology
基金
深圳市科技计划项目(200902121)
关键词
ICL
并发性白内障
虹膜张力
眼前节OCT
hnplantable contact lens(ICL)
Complicated cataract
Iris tension
Anterior segmentoptical coherence tomography