期刊文献+

高度吸收的上颌窦区种植体生物力学分析 被引量:1

Biomechanical analysis of the implants in highly absorbed maxillary sinus district
下载PDF
导出
摘要 背景:目前有限元法广泛应用于骨科生物力学分析,评价指标主要包括Max von Mises应力和应力的传递和分布概况。但由于体内的复杂生物力学环境和个体化差异明显,很难由具体的案例得出解决临床相关的方法。目的:分析高度吸收上颌窦区种植体的生物力学分布状况。方法:应用Simplant建立了一个位于上颌第二磨牙位置的5.5mm×11.0mm植入体模型;Abaqus有限元软件分别分析了在正咬合和反咬合关系条件下,在0°,30°,45°,60°,90°负载300N的同等加载下,其上颌窦区域的应力分布情况,并作了比较。结果与结论:在反咬合关系下,上颌骨内的应力集中均匀分布在牙植体颈部与皮质骨的交界处,在0°,30°,45°,60°,90°负载300N的同等加载下,Max von Mises分别是23.43,52.97,61.18,66.15,70.53MPa。在正咬合关系下,上颌骨内的应力集中不仅分布在牙植体颈部与皮质骨的交界处,而且出现了第二应力集中区,Max von Mises分别是38.64,71.22,71.62,77.65,73.21MPa,较反咬合平均高出50%左右。实验有限元分析结果表明,高度吸收上颌窦区采用反咬合设计方法更好。 BACKGROUND: The finite element method has been widely used in orthopedic biomechanics analysis by evaluating Max von Mises stress and stress delivery and distribution. However, due to the complex biomechanics environment in the body and significant individual differences, it is difficult to obtain clinical methods based on specific cases. OBJECTIVE: To analyze the biomechanical distribution of implants in the maxil ary sinus district. METHODS: An implant model, 5.5 mm×11.0 mm, located in the second molar of the maxil ary was built using Simplant. The distribution of the stress of maxil ary sinus district in the conditions of normal occlusion and crossbite under loading of 300 N at 0°, 30°, 45°, 60°, and 90°, respectively, was analyzed using Abaqus finite element software. RESULTS AND CONCLUSION: In crossbite condition, the concentration stress of von Mises was evenly distributed in the junction of the neck of dental implant and cortical bone; under the 300 N equivalent loading at 0°, 30°, 45°, 60°, and 90°, Max von Mises stress was 23.43, 52.97, 61.18, 66.15, and 70.53 MPa. In normal occlusion condition, the second stress concentration zone appeared in cortex in addition to the junction of the neck of dental implant and cortical bone, and Max von Mises stress was 30.91, 71.22, 71.62, 77.65, and 73.21 MPa under the 300N equivalent loading at 0°, 30°, 45°, 60° and 90°, about 50% higher compared with crossbite. Finite element analysis demonstrates that it is better to adopt crossbite in highly absorbed maxil ary sinus district.
出处 《中国组织工程研究》 CAS CSCD 2013年第20期3679-3686,共8页 Chinese Journal of Tissue Engineering Research
基金 国家自然科学基金资助(31070857) 南京工业大学"三创"计划资助~~
关键词 组织构建 口腔组织构建 生物力学 上颌窦区 种植体 第二磨牙 Simplant设计 Abaqus有限元 有限元模型 咬合关系 皮质骨 国家自然科学基金 tissue construction oral tissue construction biomechanics maxillary sinus implant second molar Simplant design Abaqus finite element finite element model occlusion cortical bone National Natural ScienceFoundation of China
  • 相关文献

参考文献14

二级参考文献68

共引文献37

同被引文献18

  • 1杨德圣,刘洪臣,董军,刘海亮.骨质量和种植体螺纹对种植稳定性影响的三维有限元分析[J].口腔颌面修复学杂志,2005,6(2):118-120. 被引量:15
  • 2Ashman RB, Van Buskirk WC. The elastic properties of a human mandible [J]. Adv Dent Res, 1987, 1(1): 64-67. 被引量:1
  • 3Lekholm U, Zarb GA. Patient selection and preparation. Tissue integrated prostheses: osseointegration in clinical dentistry [M]. Chicago: Quintessence Publishing Company, 1985: 199-209. 被引量:1
  • 4Tepper G, Haas R, Zechner W, et al. Three-dimensional finite element analysis of implant stability in the atrophic posterior maxilla: a mathematical study of the sinus floor augmentation [J]. Clin Oral Implants Res, 2002, 13(6): 657-665. 被引量:1
  • 5Chang SH, Lin CL, Hsue SS, et al. Biomechanical analysis of the effects of implant diameter and bone quality in short implants placed in the atrophic posterior maxilla [J]. Med Eng Phys, 2012, 34(2): 153-60. 被引量:1
  • 6Li T, Yang X, Zhang D, et al. Analysis of the biomechanical feasibility of a wide implant in moderately atrophic maxillary sinus region with finite element method[J]. Oral Surg Oral Med Oral Pathol Oral Radiol, 2012, 114(2): e1-8. 被引量:1
  • 7Lee JS, Cho IH, Kim YS, et al. Bone-implant interface with simulated insertion stress around an immediately loaded dental implant in the anterior maxilla: a three-dimensional finite Element analysis [J]. Int J Oral Maxillofac Implants, 2012, 27(2): 295-302. 被引量:1
  • 8Lee JS, Lim YJ. Three-dimensional numerical simulation of stress induced by different lengths of osseointegrated implants in the anterior maxilla [J]. Comput Methods Biomech Biomed Engin, 2013, 16(11): 1143-1149. 被引量:1
  • 9Koca OL, Eskitascioglu G, Usumez A. Three-dimensional finite-element analysis of functional stresses in different bone locations produced by implants placed in the maxillary posterior region of the sinus floor [J]. J Prosthet Dent, 2005, 93(1): 38-44. 被引量:1
  • 10Inglam S, Suebnukarn S, Tharanon W, et al. Influence of graft quality and marginal bone loss on implants placed in maxillary grafted sinus: a finite element study[J]. Med Biol Eng Comput, 2010, 48(7): 681-689. 被引量:1