Transfer Function Relating Compressive Pressure to Interfacial Stress Sensor for Biomedical Applications

Transfer Function Relating Compressive Pressure to Interfacial Stress Sensor for Biomedical Applications
下载PDF
导出
摘要 To help comfort for an amputee, it is important to understand the load distribution between the residual limb and the prosthetic socket for a prosthetic socket system. An interfacial stress sensor was presented which was capable of measuring compressive pressure and shear stress simultaneously. A mathematical model was built and an experiment was conducted to obtain the transfer function of interfacial stress sensor to compressive pressure. The results show that the sensor is capable of measuring a range of 30-217 kPa compressive pressure with a relative error of 32.15% in lower range and 6.22% in upper range. To help comfort for an amputee, it is important to understand the load distribution between the residual limb and the prosthetic socket for a prosthetic socket system. An interfacial stress sensor was presented which was capable of measuring compressive pressure and shear stress simultaneously. A mathematical model was built and an experiment was conducted to obtain the transfer function of interfacial stress sensor to compressive pressure. The results show that the sensor is capable of measuring a range of 30- 217 kPa compressive pressure with a relative error of 32. 15 % in lower range and 6.22 % in upper range.
出处 《Journal of Donghua University(English Edition)》 EI CAS 2013年第1期34-37,共4页 东华大学学报(英文版)
基金 National Natural Science Foundations of China(No.60976058,No.61274078) Innovation Program of Shanghai Municipal Education Commission,China(No.13ZZ049) Fundamental Research Funds for the Central Universities of Xidian University,China(No.K5051304005)
关键词 transfer function interfacial stress sensor residual limb prosthetic socket transfer function interfacial stress sensor residual limb prosthetic socket
  • 相关文献

参考文献31

  • 1Xu W L. The Adaptive Control for Intelligent Lower Limb . Prosthesis of Multi-motion Mode[D]. Hangzhou, Hangzhou Dianzi University, 2009: 11-12. (in Chinese). 被引量:1
  • 2Ministry of Civil Affairs of the People's Republic of China. National Sample Survey on Disability of China[M]. Beijing: China Society Press, 1991: 12 -79. (in Chinese). 被引量:1
  • 3Lin S L, Tung PC, Huang N E. Data Analysis Using a Combination of Independent Component Analysis and Empirical Mode Decomposition[J]. Physical Review. E, Statistical, Non?linear, and Soft Matter Physics, 2009, 79 ( 6) : 066705. 被引量:1
  • 4Liu Z Q. Review of the Disabled in China[J]. ChineseJournal of Rehabilitation Medicine, 2003,18(8): 493494. (in Chinese). 被引量:1
  • 5Legro M W, Reiber G, del Aguila M, et al. Issues of Importance Reported by Persons with Lower Limb Amputations and Prostheses[J].Journal of Rehabilitation Research & Development, 1999, 36(3): 155-163. 被引量:1
  • 6Klute G K, Ka1lfelz G F, CzernieckiJ M. Mechanical Properties of Prosthetic Limbs: Adapting to the Patient[J].Journal of Rehabilitation Research & Development, 2001, 38 (3) : 299-307. 被引量:1
  • 7SandersJ E, Severance M R. Assessment Technique for Computer?Aided Manufactured Sockets[J] .Journal of Rehabilitation Research and Development, 2011, 48(7) : 763-774. 被引量:1
  • 8Karchin A, Simonovsky F I, Ratner B D, et al. Melt Electrospinning of Biodegradable Polyurethane Scaffolds[J]. Acta Biomaterialia, 2011, 7 (9) : 3277-3284. 被引量:1
  • 9LaferrierJ Z, Gailey R. Advances in Lower-Limb Prosthetic Technology[J]. Physical Medicine and Rehabilitation Clinics of North America, 2010, 21(1): 87-110. 被引量:1
  • 10SandersJ E, Daly C H. Measurement of Stresses in Three Orthogonal Directions at the Residual Limb-Prosthetic Socket Interface[J]. IEEE Transactions on Rehabilitation Engineering, 1993,1(2): 79-85. 被引量:1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部