期刊文献+

新型头环、石膏背心治疗Jefferson骨折

New Type Halo-cast Fixation Apparatus for Treatment of Jefferson Fracture
原文传递
导出
摘要 目的:介绍一种新型头环石膏背心,并报告治疗Jefferson骨折的疗效.方法:用这种固定方法治疗4例Jefferson骨折,其中,1例在头环石膏背心固定下行融合术.结果:本组并发症较低,在应用头环石膏背心过程中,无神经损伤加重的病例,经临床观察和随访,治疗效果满意.结论:此固定方法是颈椎外科中很有效的一种外固定方法,具有操作简单、固定牢固和易于调整的优点,但颈椎完全性损伤伴颈髓损伤的病人为禁忌证. Objective: To introduce a new type halo-cast fixation apparatus and its curative effect for Jefferson fracture. Methods: 4 patients of Jefferson fracture were treated with this fixation apparatus. 1 of them was treated with surgical fussion in halo-cast immobilization. Results: complication The was few in the group. No patient had neurological deterioration while the halo-cast fixation apparatus were applied. Clinical observation and follow-up study demonstrated that its curative effect was satisfactory. Conclusions: The fixation apparatus should be an effective method for external immobilization for the cervical spinal surgery. The advantages of the fixation apparatus could be simple to operate, firm to immobilize and easy to adjust. But patient with complete cervical spinal cord injury could be contraindicated for this apparatus.
出处 《伤残医学杂志》 2000年第2期3-5,共3页 Medical Journal of Trauma and Disability
关键词 颈椎骨折 头环石膏 治疗 Cervical spine Fracture Halo-cast
  • 相关文献

参考文献8

  • 1张功林 葛宝丰 张军华 等.新型脊柱固定器械治疗胸腰椎脱位[J].伤残医学杂志,1997,5:12-13. 被引量:1
  • 2Coper PR, Mravilla KR, Sklar FH, et al. Halo immobilization or cervical spine fractures: Indications and results. J Neurosurg 1979,50: 603~610 被引量:1
  • 3Mirza S, Moquin RR, Anderson PA, et al. Stabilizing properties of the halo apparaturs. Spine, 1997, 22: 727~733 被引量:1
  • 4Rockswold GL, Bergman TA, Ford SE. Halo immobilization and surgical fusion: Relative indications and effectiveness in the treatment of 140 cervical spine injuries. J Trauma, 1990, 30: 893~898 被引量:1
  • 5Tomonaga T, Krag MH, Novotny JE. Clinical, radiographic,and kinematic results from an adjustable four-pad halo-vest Spine.1997,22: 1199~1208 被引量:1
  • 6Copley LA, Pepe MD, Tan V, et al. A comparative evaluation of halo pin designs in an immature skull model. Clin Orthop, 1998,357: 212~218 被引量:1
  • 7Perry J, Nickek VL. Total cervical-spine fusion for neck paralysis, J Bone Joint Surg, 1959, 41A:37~60 被引量:1
  • 8Smith MD, Johnson L J, Perra JH, et al. Biomechanical study of torque and accuracy of halo pin insertional devices. J Bone Joint Surg, 1996, 78A: 321~238 被引量:1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部