期刊文献+

髌骨骨折张力带内固定松动病例分析 被引量:3

下载PDF
导出
摘要 目的分析髌骨骨折张力带内固定松动原因,采取相应的措施,促进骨折愈合。方法 102例髌骨骨折患者行切开复位张力带内固定术,取膝前弧形或纵形皮肤切口,传统张力带内固定。结果骨折术后近期(3周内)松动1例,远期(1年后)松动11例。近期松动病例为钢缆从克氏针未折弯一端滑脱,骨折断端分离,二次手术后骨折愈合。远期松动病例8例为钢丝或钢缆从克氏针未折弯端滑脱,但骨折均愈合,其中6例髌骨纵轴延长;3例为钢丝或钢缆断裂。结论髌骨骨折切开复位张力带内固定术,剪掉多余克氏针后,应将克氏针远近端均折弯,避免钢丝或钢缆滑脱,克氏针直径选择2 mm,钢丝直径选择1 mm为佳。
作者 段天玉
出处 《基层医学论坛》 2013年第14期1804-1805,共2页 The Medical Forum
  • 相关文献

参考文献3

二级参考文献13

共引文献161

同被引文献20

  • 1Rathi A, Swamy MK, Prasantha I, et al. Percutaneous tensionband wiring for patellar fractures [J]. J Orthop Surg, 2012, 20(2): 166-169. 被引量:1
  • 2Schuett DJ, Hake ME, Mauffrey C, et al. Current treatmentstrategies for patella fractures [J]. Orthopedics, 2015, 38(6):377-384. 被引量:1
  • 3Mehdi M, Husson JL, Polard JL, et al. Treatment results offractures of the patella using pre-patellar tension wiring:analysis of a series of 203 cases [J]. Acta Orthop Belg, 1999,65(2): 188-196. 被引量:1
  • 4Hoshino CM, Tran W, Tiberi JV, et al. Complicationsfollowing tension-band fixation of patellar fractures withcannulated screws compared with Kirschner wires [J]. J BoneJoint Surg Am, 2013, 95(7): 653-659. 被引量:1
  • 5Rockwood CA Jr. Disorders of the acromioclavicular joint//Rockwood CA Jr, Matsen FA Ⅲ, eds. The shoulder [M].Philadelphia: WB Saunders, 1985: 413-476. 被引量:1
  • 6B-stman O, Kiviluoto O, Nirhamo J. Comminuted displacedfractures of the patella [J]. Injury, 1981, 13(3): 196-202. 被引量:1
  • 7Petrie J, Sassoon A, Langford J. Complications of patellarfracture repair: treatment and results [J]. J Knee Surg, 2013,26(5): 309-312. 被引量:1
  • 8Smith ST, Cramer KE, Karges DE, et al. Early complicationsin the operative treatment of patella fractures [J]. J OrthopTrauma, 1997, 11(3): 183-187. 被引量:1
  • 9Wardak MI, Siawash AR, Hayda R. Fixation of patellafractures with a minimally invasive tensioned wire method:compressive external fixation [J]. J Trauma Acute Care Surg,2012, 72(5): 1393-1398. 被引量:1
  • 10Thelen S, Schneppendahl J, Baumg-rtner R, et al. Cycliclong-term loading of a bilateral fixed-angle plate incomparison with tension band wiring with K-wires orcannulated screws in transverse patella fractures [J]. KneeSurg Sports Traumatol Arthrosc, 2013, 21(2): 311-317. 被引量:1

引证文献3

二级引证文献15

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部