期刊文献+

600MW机组首台折流杆闭冷器的选型及应用

Selection and Application of 600MW unit Rod Baffle Closed cold
下载PDF
导出
摘要 关于外导流折流杆闭冷器首次在600 MW超临界燃煤发电机组行运情况的分析总结,该技术闭冷器具有换热效高、流动阻力小、结构紧凑、防振性强、不易结垢等优点,具重要应用价值。 About guide baffle rod outside the closed cycle cooling water heat exchanger in 600 MW supercritical coal-fired power generating units for the first time operation condition analysis summary,The technology of closed cycle cooling water heat exchange equipment has a high heat transfer efficiency,small flow resistance,compact structure,strong vibration resistance,not easy to scale advantages,has the important application value.
出处 《大众科技》 2013年第5期91-93,共3页 Popular Science & Technology
关键词 600MW超临界燃煤发电机组 折流杆换热器 防振 免维护 换热效率 600 MW supercritical coal-fired power generating units baffle rod the exchanger: To prevent vibration Free maintenance heat exchange efficiency
  • 相关文献

参考文献5

  • 1兰州石油机械研究所主编.换热器(上册)[M].中国 石化出版. 被引量:2
  • 2姚仲鹏等编..传热学[M].北京:北京理工大学出版社,1995:308.
  • 3中华人民共和国国家标准.GB151-1999,管壳式换热器[M].北京:中国标准出版社. 被引量:1
  • 4钱颂文主编..换热器设计手册[M].北京:化学工业出版社,2002:525.
  • 5西安热工研究有限公司.华能汕头发电厂3号机组性能考核试验报告. 被引量:1

共引文献1