期刊文献+

不同载体碘伏的杀菌效果比较 被引量:13

EXPERIMENTAL COMPARISON OF GERMICIDAL EFFICACY OF IODOPHOR USING DIFFERENT CARRIERS
下载PDF
导出
摘要 EDA-Ⅰ是以季铵为载体的络合碘,PVP-Ⅰ是以聚乙烯吡咯烷酮为载体者。采用菌片定量杀菌试验,对两者杀菌作用进行了比较。均以有效碘 100mg/L溶液对大肠杆菌作用10min,对金黄色葡萄球菌、白色念珠菌作用 20 min,杀灭率均达 100%。 25%~50%小牛血清对 PVP-Ⅰ杀菌作用的影响较对EDA-Ⅰ者大。在54℃存放14 d,EDA-Ⅰ与PVP-Ⅰ有效碘下降率分别为8.83%与6.77%。 EDA-I is complex iodine with quarternary ammonium as carrier and PVP-I uses polyvinylpyrrolidone as carrier. Bacterial carrier quantitative germicidal test was used to compare the germicidal efficacy of these two iodophor. Solution of either iodophor containing available iodine 100 mg / L could kill 100% of Escherichia coli after 10 min contact and 100% of Staphylococcus aureus or Candida albicans after 20 min contact. The influence of 25%-50% calf serum was greater on germicidal efficacy of PVP-I than on that of EDA-I. After storing at 54℃ for 14 days, the rates of decrease in available iodine of EDA-I and PVP-I were 8.83% and 6.77% respectively.
出处 《中国消毒学杂志》 CAS 2000年第3期165-168,共4页 Chinese Journal of Disinfection
关键词 EDA-Ⅰ PVP-Ⅰ 稳定性 碘伏 EDA-Ⅰ PVP-Ⅰ germicidal efficacy Escherichia coli Slaphylococcus aureus Candida albicans stability