摘要 自回归功率谱密度(AR-PSD)方法的基础是生物组织的离散散射体模型〔超声体模〕理论,该模型认为生物组织为半规则的散射体分布的,这种方法是基于温度和频移的相关特性。本文介绍超声回波信号对HIFU(High Inten-sity Focused Ultrasound)治疗的测温技术,从测温模型和算法,实验仪器的设计和构建,仿真和离体实验中获取了一套有效的测温方法,利用Matlab7.1和VC++6.0作为工具对超声回波信号进行计算机仿真,并从实验获得的超声回波信号中分析出具体的温度变化,验证了算法的可行性。 Autoregressive power spectral density (AR-PSD) approach is based on biological tissue model of discrete scattering theory [ultrasound phantom of the model^that the biological tissue is semi-regular distribution of the scattering body, this method is based on the temperature and frequency shift-related features. In this paper, ultrasonic echo signal HIFU (High Intensity Focused Ultrasound) treatment temperature measurement, temperature measurement models and algorithms from experimental design and build equipment, simulation and in vitro experiments to obtain a valid temperature measurement, Matlab7.1 and VC + +6.0 use as a tool for computer simulation of ultrasonic echo signals, and obtained from the experimental analysis of ultrasonic echo signals from a specific temperature to verify the feasibility of the method.
作者 王亚 傅伟
出处 《电子设计工程》 2013年第9期7-10,共4页 Electronic Design Engineering
基金 江苏省高校科研成果产业化推进工程项目(JH10-42) 淮安市科技支撑计划(HAG09006 HAG2010049 SN12048) 淮安市创新载体平台建设计划(HAP201010)
关键词 无损测温 AR模型 功率谱密度函数 算法 noninvasive temperature estimation AR model power spectrum density algorithm
  • 相关文献

参考文献7

二级参考文献35

  • 1龚忠兵,王保华,姚名,翁海文,冉昊.HIFU治疗下生物体焦域温度分布的研究与应用[J].上海生物医学工程,2004,25(4):29-32. 被引量:13
  • 2沈阳,寿文德,耿晓鸣,王信宏.HIFU温度场可视化测量初探[J].应用声学,2005,24(1):24-27. 被引量:5
  • 3钟徽,万明习,江一峰,王素品.高强度聚焦超声软组织损伤超声监控成像与评价方法[J].声学学报,2006,31(3):247-254. 被引量:22
  • 4Solomon S B, Nicol T L, Chan D Y, et al. Histologic evolution of high intensity focused ultrasound in rabbit muscle. Invest Radiol, 2003,38: 293-301. 被引量:1
  • 5Jacobsen S, Stauffer E Non-invasive temperature profile estimation in a lossy medium based on multi-band radiometric signals sensed by a microwave dual-purpose body-contacting antenna.Int J Hyperthermia, 2002,18: 86-103. 被引量:1
  • 6Hynynen K, Darkazanli A, Unger E, et al. MR/guided noninvasive ultrasound surgery. Med Phys, 1993,20: 107-115. 被引量:1
  • 7Muacevic A, PeUer M, Ruprecht L, et al. Image guided interstitial laser thermotherapy: a canine model evaluated by magnetic resonance imaging and quantitative autoradiography. Acta Neurochir (Wien), 2005,147: 175-185. 被引量:1
  • 8McDannold N J, King RL, Jolesz FA, et al. Usefulness of MR imaging-derived thermometry and dosimetry in determining the threshold for tissue damage induced by thermal surgery in rabbits. Radiology, 2000, 216: 517-523. 被引量:1
  • 9Bohris C, Schreiber WG, Jenne J, et al. Quantitative MR temperature monitoring of high- intensity focused ultrasound therapy. Magn Reson Imaging, 1999,17: 603-610. 被引量:1
  • 10Bohris C, Jenne JW, Rastert R, et al. MR monitoring of focused ultrasound surgery in a breast tissue model in vivo. Magn Reson Imaging, 2001,19:167- 175. 被引量:1