摘要 2012年3月发现锅炉饱和蒸汽钠离子含量连续超标,最大达到76μg/L。通过检查、分析研究和实验结果,提出汽包裂纹处理的方法及注意事项。将锅水协调pH-磷酸盐处理工艺改为低磷酸盐处理工艺,并修改相应控制标准,提出解决汽包水位偏差和波动的相应对策。经处理,饱和蒸汽钠离子含量达标。 In March 2013, it was found that the sodium (Na + ) content in saturation steam continuously exceeded the stand- ards, and the maximum value reached 76μg/L. Through the inspection, analysis and test results, the treatment and cautions for the cracks of steam drum are proposed. Meanwhile, the pH - phosphate treatment process is changed to low phosphate treatment process, and the relevant control standards are revised. The countermeasures for the deviation and fluctuation of wa- ter level in steam drum are proposed too. After the treatment, the sodium content in saturation steam reaches the standards.
作者 彭卫红
出处 《四川电力技术》 2013年第2期84-86,共3页 Sichuan Electric Power Technology
关键词 进口亚临界机组 饱和蒸汽含钠量 超标 措施 imported subcritieal units sodium content in saturation steam exceeding standard measure
  • 相关文献

参考文献4

  • 1四川巴蜀江油发电厂,四川巴蜀江油发电厂化学运行规程[s]. 被引量:1
  • 2四川巴蜀江油发电厂出版,四川巴蜀江油发电厂锅炉运行规程[s]. 被引量:1
  • 3四川巴蜀江油发电厂出版,四川巴蜀江油发电厂锅炉检修规程[s]. 被引量:1
  • 4电厂化学水处理[M].武汉:大学出版社. 被引量:1