期刊文献+

对TGS装置平板准直距离影响探测效率的探究

The Research of Relationship Between the Distance of Flat Panel Collimator and the Efficiency of Detector
下载PDF
导出
摘要 TGS系统的平板准直对探测效率及最后的计算有很重要的影响,通过MCNP5程序建立TGS模型,考虑了核退役中几种常见的并且密度相差较大的物质(玻璃棉、木屑、水、水泥、铝合金等),放射源使用常用投射源60Co,以0.5 cm的步进距离进行模拟试验,最后根据结果得出准直器距离在3~3.5 cm时可获得相对较好的效果。 The paper use MCNP5 procedures to build the TGS device model,it studies the effect of distance be- tween the collimators to the detection efficiency by adjusting the detector front tablet, accounting several Nudear Decommissioning substances frequently encountered. The simulation uses 60 Co as the source and uses the distanee step of 0.5 cm, and the results shows that the optimal distance is 3 to 3.5 cm.
出处 《核电子学与探测技术》 CAS CSCD 北大核心 2013年第1期35-37,共3页 Nuclear Electronics & Detection Technology
关键词 蒙特卡洛模拟 层析γ扫描 平板准直 探测效率 Monte Carlo simulation TGS tablet collimation detection efficiency
  • 相关文献

参考文献7

二级参考文献20

  • 1朱文凯,陈军,熊建平,陈坤,陈益军.ISOCS系统无源效率刻度测量方法的准确性检验[J].核电子学与探测技术,2005,25(3):287-290. 被引量:34
  • 2Prettyman T H, Betts S E, Taggart D P, et al. Field Experience with a Mobile Tomographic Nondestructive Assay System. Los Alamos National Laboratory, 1995. LA-UR-95-3501. 被引量:1
  • 3Wang T F, Martz H E, Roberson G P, et al. Three dimensional imaging of a molten-salt-extracted plutonium button using both active and passive gamma-ray computed tomography. Nucl Instrum Methods Phys Res A, 1994, 353:672-677. 被引量:1
  • 4Goodman D, Jackson J A, Martz H E, et al. An Active And Passive Computed Tomography Algorithm With A Constrained Conjugate Gradient Solution. Lawrence Livermore National Laboratory, 1998. UCRL-JC-130818. 被引量:1
  • 5Robert J E, Thomas H P, Sheppard G A. Tomographic gamma scanning to assay heterogeneous radioactive waste. Nucl Sci Eng, 1994, 118: 145-152. 被引量:1
  • 6Venkataraman R, Croft S, Villani M, et al. Performance study of the tomographic gamma scanner for the radioassay of drums. In: Proceedings of 45th Annual INMM Meeting. Orlando: FL, 2004. 18-22. 被引量:1
  • 7Croft S, Venkataraman R, Villani M. Characterizing a tomographic gamma scanner. In: Proceedings of 45th Annual INMM Meeting. Orlando: FL, 2004.18-22. 被引量:1
  • 8Bronson F L, Wang L. Validation of the MCNP Monte Carlo code for germanium detector gamma effieiency calibrations. In: Proceedings of Waste Management'96. Tucson: AZ, 1996. 被引量:1
  • 9Ewa I O B, Bodizs D, Czifrus S, et al. Monte Carlo determination of full energy peak efficiency for a HPGe detector. Appl Radiat Isot, 55(2001): 103-108. 被引量:1
  • 10Selcow E C, Dobrzeniecki A B, Yanch J C, et al. An evaluation of the Monte Carlo simulation of SPECT projection data using MCNP and SimSPECT. In: ICONE 4: ASME/JSME Intemational Conference on Nuclear Engineering, LA: New Orleans, 1996. BNL-62803. 被引量:1