复方聚乙二醇电解质散联合番泻叶应用于结肠镜检查前肠道准备237例 被引量:6

原文传递
导出
摘要 目的观察复方聚乙二醇电解质散合用小剂量番泻叶及单纯应用复方聚乙二醇电解质散对肠道清洁程度及患者口服药物后不适发生情况。方法对行肠镜检查的患者分为两组进行检查前肠道准备。聚乙二醇+番泻叶组应用复方聚乙二醇电解质散1盒(75g)+番泻叶1.5—3g,聚乙二醇组应用复方聚乙二醇电解质散2盒(150g)对两组患者的肠道清洁程度进行比较。结果聚乙二醇+番泻叶组237例,肠道清洁率90.7%,患者口服药物后不适发生率18.0%。聚乙二醇组212例,肠道清洁率69.7%,患者口服药物后不适发生率67.0%。二者肠道清洁率及患者口服药物后不适发生率差异有统计学意义。结论应用复方聚乙二醇电解质散合用番泻叶进行肠道清洁优于单纯应用复方聚乙二醇电解质散,两者合用后患者不适发生率减少,故推荐临床上行结肠镜检查时,使用复方聚乙二醇电解质散合用番泻叶进行肠道清洁。
作者 王剑鸿
出处 《中国基层医药》 CAS 2013年第7期1075-1076,共2页 Chinese Journal of Primary Medicine and Pharmacy
  • 相关文献

参考文献10

二级参考文献80

共引文献182

同被引文献49

  • 1林坚雄,陈艺,刘羡纬.两种口服药对行结肠镜检查肠道清洁效果的评价[J].黑龙江医学,2013,37(6):468-470. 被引量:5
  • 2周永学,王倩,张筱军.芒硝的临床运用与药理研究[J].陕西中医学院学报,2007,30(1):54-55. 被引量:67
  • 3谢金彪.大肠癌防与治[M].西安:西安交通大学出版社,2010:34. 被引量:4
  • 4Bitoun A, Ponchon T, Barthet M, et al. Results of a prospective randomised multicentre controlled trial comparing a new 2-L as- corbic acid plus polyethylene glycol and electrolyte solution vs. sodium phosphate solution in patients undergoing elective colono- scopy[J]. Aliment Pharmacol Ther, 2006,24 ( 11 / 12) : 1631-1642. 被引量:1
  • 5DiPalma JA, McGowan J, Cleveland MV. Clinical trial : an efficacy evaluation of reduced bisacodyl given as part of a polyethylene glycol electrolyte solution preparation prior to colonoscopy [J]. Aliment Pharmacol Ther, 2007,26 (8) : 1113-1119. 被引量:1
  • 6Schanz S, Kruis W, Mickisch O, et al. Bowel preparation for colo- noscopy with sodium phosphate solution versus polyethylene glycol-based lavage:a multicenter trial [J]. Diagn Ther Endosc, 2008,2008:713521. 被引量:1
  • 7Wexner SD, Beck DE, Baron TH, et al. A consensus document on bowel preparation before colonoscopy:prepared by a task force from the American Society of Colon and Rectal Surgeons (ASCRS), the American Society for Gastrointestinal Endoscopy (ASGE), and the Society of American Gastrointestinal and Endoscopic Sur- geons (SAGES) [J]. Gastrointest Endosc, 2006,63 (7) : 894-909. 被引量:1
  • 8Anderson JC, Gonzalez JD, Messina CR, et al. Factors that pre- dict incomplete colonoscopy :thinner is not always better[J]. Am J Gastroenterol, 2000,95 (10) : 2787. 被引量:1
  • 9Froehlich F, Wietlisbaeh V, Gonvers J J, et al. Impact of colonic cleansing on quality and diagnostic yield of eolonoscopy : the Eu- ropean Panel of Appropriateness of Gastrointestinal Endoscopy European multicenter study[J]. Gastrointest Endose, 2005,61 (3) : 378-384. 被引量:1
  • 10Bernstein C,Thorn M, Monsees K, et al. A prospective study of factors that determine cecal intubation time at colonoscopy [J]. Gastrointest Endosc, 2005,61 (1) : 72-75. 被引量:1