期刊文献+

5种免提取试剂盒检验滤纸血痕结果的比较 被引量:12

Comparative study of bloodstain on the filter paper with five different direct PCR amplification kits
原文传递
导出
摘要 目的探讨5种免提取试剂盒对滤纸血痕样本检验的效果。方法陈旧滤纸血痕(存放时间12~14个月)及新鲜滤纸血痕(存放时间小于1个月)各920份,分别随机分为5组。应用AGCU 17+1、Goldeneye 20A、Powerplex16HS、Identifiler Plus、Identifiler Direct 5种免提取试剂盒进行检验,对比各组检验结果。结果陈旧滤纸血痕5种试剂盒的检验成功率为98.91%~100%,各组间无差异(P>0.05);新鲜滤纸血痕,Identifiler Plus和Identifiler Direct试剂盒检验成功率高于AGCU17+1、Goldeneye 20A及Powerplex 16HS试剂盒(P<0.01);将样本做陈旧化处理后再用成功率较低的3种试剂盒进行检验,成功率分别升至100%、99.46%、99.46%;Identifiler Plus试剂盒扩增循环27次效果优于28次。结论本文5种试剂盒均可用于滤纸血痕的直接扩增检验,但使用AGCU17+1、Goldeneye 20A及Powerplex 16HS试剂盒需将新鲜血痕做陈旧化处理;Identifiler Plus试剂盒需将循环次数降为27次。 Objective To evaluate the difference of genotyping profiles of bloodstain samples on the filter paper with five different direct PCR amplification kits.Methods 920 aged bloodstains samples on the filter paper(storage time:12 to 14 months) and 920 fresh bloodstain samples on the filter paper(storage time:less than 1 months) were randomly divided into five groups respectively,and were amplified with AGCU 17+1,Goldeneye 20A,Powerplex 16 HS,Identifiler Plus and Identifiler Direct kits respectively.The results of each groups should be compared each other.Results The success rate of aged bloodstain samples on the filter paper amplified with the five kits ranged from 98.91% to 100%,there were no significant differences between the groups(P0.05);The success rate of fresh bloodstains on the filter paper amplified with Identifiler Plus and Identifiler Direct kits was higher than AGCU17+1,Goldeneye 20A and Powerplex 16 HS kits(P0.01);After placing the fresh bloodstains on the filter paper of the three groups with lower success rate at 99℃ for one hour,the success rate were 100%,99.46% and 99.46%;The results of cycle number were 27 were better than 28 with Identifiler Plus kit.Conclusions The five kits used in our study were suitable for direct amplification of bloodstains on the filter paper,while the fresh bloodstains on the filter paper should be ovened at 99℃ for one hour befor direct amplification with AGCU17+1,Goldeneye 20A and Powerplex 16 HS kits;The cycle number should be reduced to 27 with Identifiler Plus kit.
出处 《中国法医学杂志》 CSCD 2013年第1期49-51,共3页 Chinese Journal of Forensic Medicine
关键词 法医物证学 滤纸血痕 免提取试剂盒 直接扩增检验 forensic biological evidence bloodstain on the filter paper direct PCR amplification kits direct amplification test
  • 相关文献

参考文献6

  • 1邹广发.AGCU免提取STR荧光检测试剂盒的验证[J].刑事技术,2010,35(3):23-25. 被引量:7
  • 2王洁,黄艳梅,张庆霞,王静,唐晖,焦章平,刘雅诚.国产Goldeneye^(TM) 20A试剂盒性能指标验证[J].中国法医学杂志,2012,27(1):12-15. 被引量:9
  • 3Ensenberger M G,Thompson J,Hill B,et al.Developmental validation of the PowerPlex 16 HS System:animproved 16-locus fluorescent STR multiplex[J].ForensicSci Int Genet,2010,4(4):257-264. 被引量:1
  • 4Wang D Y,Chang C W,LagacéR E,et al.Developmentalvalidation of the AmpFSTRIdentifilerPlus PCRAmplification Kit:an established multiplex assay withimproved performance[J].J Forensic Sci,2012,57(2):453-465. 被引量:1
  • 5Wang D Y,Chang C W,LagacéR E,et al.Developmentand validation of the AmpFSTRIdentifilerDirect PCRAmplification Kit:a multiplex assay for the directamplification of singlesource samples[J].J Forensic Sci,2011,56(4):835-845. 被引量:1
  • 6Bu Y,Huang H,Zhou G.Direct polymerase chain reaction(PCR)from human whole blood and filter-paper-dried bloodby using a PCR buffer with a higher pH[J].Anal Biochem,2008,375(2):370-372. 被引量:1

二级参考文献8

共引文献14

同被引文献76

  • 1罗凯,李明谦,曾途.隐性血痕在命案现场中的运用[J].广西警官高等专科学校学报,2007,20(S1):61-63. 被引量:3
  • 2袁自闯,李海燕,赵凯,宁忠,唐振亚,邝玉斌,欧桂生.3种分离提取混合斑精子DNA的方法比较[J].中国法医学杂志,2007,22(5):325-326. 被引量:10
  • 3巴华杰,刘冰泉,马骏,朱爱华,林子清.Chelex-100法提取滤纸血痕DNA影响因素的比较[J].法医学杂志,2007,23(5):347-348. 被引量:9
  • 4Bulter JM, Hill CR. Biology and genetics of new autosomal STR loci useful for forensic DNA analysis [ J]. Forensic Sci Rev, 2012,24(1):16 -26. 被引量:1
  • 5Hares DR. Expanding the CODIS core loci in the United States [Jl. Forensic Sci Int Genet, 2012, 6(1): 52 -54. 被引量:1
  • 6Gill P. A new method of STR interpretation using inferential logic development of a criminal intelligence database[ J]. Int J Leg Med,1996,109(1) :14 -22. 被引量:1
  • 7Hering S, Edelmann J, Dressler J. Sequence variations in the primer binding regions of the highly polymorphic STR system SE33[J]. Int J Legal Med,2002,116(6) :365 -367. 被引量:1
  • 8Bu Y, Huang H, Zhou G. Direct polymerase chain reaction (PCR) from human whole blood and filter-paper-dried blood by using a PCR buffer with a higher pI-t[J]. Anal Biochem, 2008, 375(2): 370-372. 被引量:1
  • 9Akane A, Matsubara K, Nakamura H, et al. Identification of the heme compound copurified with deoxyribonucleic acid (DNA) from bloodstains, a major inhibitor of polymerase chain reaction ( PCR ) amplification [ J ]. J Forensic Sci, 1994, 39(2): 362-372. 被引量:1
  • 10林宏昭,胡佩儒.组蛋白与组蛋白的相互作用[J].锦州医学院学报,1980,4:49-65. 被引量:1

引证文献12

二级引证文献40

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部