摘要 光电倍增管(Photomultiplier Tube,PMT)是荧光免疫分析仪的重要部件,随着开关电源(SMPS)技术的发展,此技术已广泛应用于设计光电倍增管用高压电源,但双极输出型高压稳压电源还未广泛应用。本文主要介绍双极输出可调高压电源电路的结构原理及电阻链分压为基础的应用电路的设计与实现技术。经过实际应用,该电路具有调压灵活可靠、稳压精度高、抗干扰能力强等特点。 The photomultiplier tube (PMT) is a core component in a fluorescence immunoassay (FIA) system. With the development of the switching mode power supply (SMPS) technology, SMPS is more and more popular with a PMT power design. However there are few applications of bipolar power supply. This paper introduces the structure principle of bipolar power supply and application circuits based on resistance chain partial pressure. After practice application, this circuit is proved to be more stable, more precision, and more convenient.
出处 《中国医疗设备》 2013年第3期31-33,共3页 China Medical Devices
关键词 高压电源 光电倍增管 光子计数 倍压整流 荧光信号传感器 high voltage power supply photomultiplier tube photon counting double voltage rectifying fluorescence signal sensor
  • 相关文献

参考文献10

二级参考文献187

共引文献80

同被引文献33

  • 1赵先英,舒为群,曹佳,刘毅敏.医院污水中放射性物质排放状况研究[J].西南国防医药,2005,15(1):29-31. 被引量:6
  • 2海燕.低噪声大动态范围前置跨阻放大器的研制[D].重庆:重庆邮电大学,2006. 被引量:1
  • 3中华人民共和国卫生部.GBZ133-2002医用放射性废物管理卫生防护标准[S].北京:中国标准出版社,2002:1-12. 被引量:2
  • 4张娅雯.霍尔电流传感器设计[C].南京:江苏大学机械工程学院,2011. 被引量:1
  • 5国家环保总局.医院废液处理技术指南[S].国家环保总局,2004. 被引量:1
  • 6Renker D. New trends on photodetectors[J]. Nuclear Instruments and Methods in Physics Research, 2007, 571:1-6. 被引量:1
  • 7Jelena Ninkovic. Recent development in silicon photomultipliers[J]. Nuclear Instruments and Methods in Physics Research, 2007, 580:1020-1022. 被引量:1
  • 8MusienkoYuri. Advances in multipixel Geiger-mode avalanche photodiodes[J]. Nuclear Instruments and Methods in Physics Research, 2009, 598:213-216. 被引量:1
  • 9Dhulla V, Gudkov G, Stepoukhovitch A, et al. Single photon detection module for multi - channel detection of weak fluorescence signals[J]. Proceedings of SPIE - The International Society for Optical Engineering,2005,16 (3) :45 - 46. 被引量:1
  • 10Minoru Waki D, NorihiroMizoshita D, Maegawa Y, et al. Enhanced Fluorescence Detection of metal ions using light - Harvesting mesoporous organosiliea [ J ]. Chemistry - A European Journal, 2012,18(7) :1992 - 1998. 被引量:1