期刊文献+

电流互感器运行中常见问题的分析及其预防措施 被引量:2

Analysis and Countermeasures on the Problems during the Operation of Current Transformer
下载PDF
导出
摘要 电流互感器作为电流变换设备在电力系统生产运行中起着非常重要的作用,它为测量仪表、保护装置的正常运行提供电源.但电流互感器励磁特性差和二次回路误接线、断线、分流等问题严重影响电网系统的安全稳定运行.为了解决上述问题,根据生产运行中的实际经验,对上述问题产生的原因进行了分析,并提出了预防处理措施. The current transformer as current transformation equipment plays a very important role in the operation of power system. It provides power supply for the normal operation of protection devices and measuring meters, but some problems such as poor excitation characteristics of the current transformer, secondary loop false wiring, disconnection, shunt seriously have been affecting the safe and stable operation of power grid system, and disturbing the production, operation and maintainer. In order to avoid the above problems appearing in the future work and deal with these problems properly, the causes of these problems are analyzed and the preventive measures are put forward according to the actual experience.
作者 王国松
机构地区 渑池县电业局
出处 《华北水利水电学院学报》 2013年第1期103-105,共3页 North China Institute of Water Conservancy and Hydroelectric Power
关键词 电流互感器 励磁特性 二次回路误接线 断线 分流 处理措施 current transformer excitation characteristics secondary loop false wiring broken wire shunt measures
  • 相关文献

参考文献3

  • 1刘介才.工厂供电[M].北京:机械工业出版社,1997.. 被引量:7
  • 2陈家斌,张露江.继电保护、二次回路、电源故障处理方法及典型案例[M].北京:中国电力出版社,2012:143-144. 被引量:1
  • 3王显平主编..发电厂、变电站二次系统及继电保护测试技术[M].北京:中国电力出版社,2006:349.