摘要 介绍了漳山电厂对2台300 MW发电机组上开展了一系列节能降耗工作,并针对高压变频应用中存在问题和关键技术,提出了解决方法。通过实例分析说明,为火力发电厂的技术人员进行高压变频节能进行可行性分析提供帮助,为进行节能预算和投资回报分析提供参考,为进一步在电力系统中推广高压变频的应用提供理论指导。 Introduced the energy saving work carried out for 2 units of 300 MW generating sets in Zhangshan power plant, pre- sented solutions in view of the problems and key technologies of the application of high voltage frequency conversion. This paper analyzed with an example to assist the feasibility analysis of high voltage frequency conversion energy saving for the thermal power plant by technicians, to provide references for the analysis of energy budget and return of investment, and to provide theoretical guidance for further promoting the application of high voltage frequency conversion in power system.
出处 《能源与节能》 2013年第2期21-23,共3页 Energy and Energy Conservation
关键词 漳山电厂变频改造 重要性 经济效益 frequency conversion transformation of Zhangshan Power Plant importance economic benefit