期刊文献+

40万吨/年尾油加氢装置的腐蚀现状分析

Analysis of Corrosion of 400000 t/a Unconverted-oil Hydrocracker Installation
下载PDF
导出
摘要 在高温下的氢和硫化氢以及在低温下的硫化氢、硫化铵和氯化铵是造成尾油加氢装置腐蚀的主要原因。通过分析40万吨/年尾油加氢装置相关介质数据,得出尾油加氢装置高温下的氢腐蚀、硫化氢腐蚀和铵盐冲刷腐蚀的机理,并提出预防措施。 The main reason of corrosion of unconverted-oil hydrocracker installation is hydrogen and hydrogen sulfide under the condition of high temperature and hydrogen sulfide, ammonium sulfide and ammonia chloride under low temperature condition. Through the analysis of date of medium of 400000 t/a unconverted-oil hydrocracker installation, corrosion mechanism of hydrogen corrosion and hydrogen sulfide corrosion under the condition of high temperature and ammonium salt Erosion-corrosion. The prevention measures were put forward.
作者 董振
出处 《广东化工》 CAS 2013年第4期111-112,93,共3页 Guangdong Chemical Industry
关键词 裂化尾油加氢 氢气 硫化氢 铵盐 腐蚀 unconverted-oil hydrocracker hydrogen: hydrogen sulfide: ammonium sulfide corrosion
  • 相关文献

参考文献3

  • 1权红旗.加氢装置的腐蚀与防护[J].石油化工设备技术,2005,26(1):56-58. 被引量:23
  • 2何杨松..锻焊式加氢反应器的选材分析 [D].华东理工大学,2002:
  • 3马连刚.加氢精制装黄的腐蚀与防护[C].加氢装置生产技术交流会论文集,2008:687-697. 被引量:1

二级参考文献9

共引文献22

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部