摘要 自制了一个137单元分立促动器的连续镜面式变形镜,用于自适应光学相关技术的研究。首先,利用Zygo激光干涉仪对变形镜的静态性能进行了测试,包括面形测试、单个促动器的响应测试和耦合测试;然后,针对变形镜的校正能力,分别进行了Zernike多项式拟合和展平测试,并利用自适应光学实验平台实验验证了变形镜的校正能力;最后,利用搭建的快速响应测量平台测试了变形镜及其驱动电路的动态响应性能。测试及实验表明,137单元变形镜静态展平后的面形RMS值优于λ/50,PV值优于0.18λ(λ=632.8nm);能够对前7阶Zernike多项式进行较好的拟合和校正;变形镜及其高压驱动器的动态响应优于1kHz;该变形镜能使系统的Strehl ratio从小于0.1提高到优于0.9,明显改善了系统的成像能力。 A 137-element Deformable Mirror(DM) was manufactured by ourselves to carry out the research on the adaptive optics.First,a Zygo interferometer was used to test the static characteristics of the DM,which included figure tests,response tests of single actuators and coupling tests.Then,Zernike polynomial fitting and surface flattening were performed to test the correction capability of the DM,respectively,and the correction capability was also verified experimentally at an adaptive optics test-bed.Finally,a fast response measurement system was built up to test the dynamic response abilities of the DM and its drive electronics.The tests and experiments show that the surface of the DM after flatten calibration has the RMS and PV better than λ/50 and 0.18λ(λ=632.8 nm),respectively.Furthermore,the DM can fit and correct the first 7 order Zernike polynomials reasonably.The dynamic responses both of the DM and its high voltage driver are faster than 1 kHz.The tests in the indoor adaptive optics system show that the DM improves the system's Strehl ratio from less than 0.1 to better than 0.9,which enhances the imaging capability of the system greatly.
出处 《光学精密工程》 EI CAS CSCD 北大核心 2013年第2期267-273,共7页 Optics and Precision Engineering
基金 国家863高技术研究发展计划资助项目(No.2011AAXXX1003)
关键词 自适应光学 变形镜 性能测试 校正能力 动态响应 adaptive optics deformable mirror performance test correction capability dynamic response
  • 相关文献

参考文献13

  • 1HARDY J W. Adaptive Optics for Astronomical Telescopes [M]. New York.. Oxford University Press, 1998. 被引量:1
  • 2LOWREY W H, WYNIA J L, EALEY M A. Char- acterization of three advanced deformable mirrors [J]. SPIE, 1998, 3433:388-393. 被引量:1
  • 3PRICE T R,EALE M A. Adaptive tertiary mirror for segmented mirror control [J]. SPIE, 2004, 5166.157-164. 被引量:1
  • 4宁禹..双压电片变形反射镜的性能分析与应用研究[D].国防科学技术大学,2008:
  • 5HAMELINCK R, ROSIELLE N, KAPPELHOF P, et al.. Large adaptive deformable membrane mirror with high actuator density [J]. SPIE, 2004, 5490: 1482-1492. 被引量:1
  • 6COMELISSEN S A, BIERDEN P A, BIFANO T G. A 4096 element continuous facesheet MEMS de-formable mirror for high-contrast imaging [J ]. SPIE, 2008, 6888: 68880V. 被引量:1
  • 7CAO ZH L, MU Q Q, HU L F, et al.. Prelimina- ry use of nematic liquid crystal adaptive optics witha 2. 16-meter reflecting telescope[J]. Optics Ex- press, 2009,17(4) :2530-2537. 被引量:1
  • 8GAI.LIENI D, ANACLERIO E, GLAZZARINI P, et al.. LBT adaptive secondary units final design and construction [J]. SPIE, 2003, 4839:765-772. 被引量:1
  • 9PATERSON C, MUNRO I, DAINTY C. A low cost adaptive optics using a membrane mirror [J].Optics Express, 2000, 6 : 175-185. 被引量:1
  • 10SIVARAMAKRISHNAN A, OPPENHEIMER B R. Deformable mirror calibration for adaptive optics systems[J]. SPIE, 1998,3353:910-916. 被引量:1

二级参考文献10

  • 1邵兵,孙立宁,曲东升,王建国,秦昌.自由空间光通信ATP系统中精瞄偏转镜的设计[J].光学精密工程,2006,14(1):43-47. 被引量:19
  • 2J.M.Spinhirne, JG Mien, G.A. Ameer, et, al. The Starfire Optical Range 3.5m Telescope Adaptive Optical System[C]//SPIE, 1998, 3355: 22-33. 被引量:1
  • 3Francois Rigant, Review of astronomical adaptive optics systems on medium-sized (1.5-5m) telescopes[C]//OSA 's Summer Topic Meeting on Adaptive Optics, Maui, Hawaii, USA, July 7-12, 1996. 被引量:1
  • 4John W.Hardy. Adaptive optics for astronomical telescopes[M]. New York Oxford, Oxford University Press, 1998. 被引量:1
  • 5B. R. Oppenheimer, D. Palmer, R. Dekany, et, al. Investigating a Xinetics Inc. Deformable Mirror[C]//SPIE, 1997, 3126: 569-579. 被引量:1
  • 6William G. Thorburn, Leonard Kaplan. A low voltage electrodistortive mirror system for wave front control[C]//SPIE, 1991, 1543: 52-63. 被引量:1
  • 7S. M. Hues et, al. Effect of PZT and PMN Actuator Hysteresis and Creep on Nanoindentation Microscopy[J]. IEEE, 1994, 65: 1561. 被引量:1
  • 8Michael F.Smutko. Design and construction of deformable mirrors for the University of Chicago adaptive optics system[C]//Publictions of the Astronomical society of the Pacific, 1997, 109: 804-814. 被引量:1
  • 9Gleb Vdovin, Oleg Soloviev, Alexander Samokhin,et,al. Correction of low order aberrations using continuous deformable mirrors[C]//OPTICS EXPRESS, 2008, 16(5): 2859-2866. 被引量:1
  • 10凌宁,李明全,张正荣,邢薇.压电陶瓷的δ—V曲线测试[J]光学工程,1985(06). 被引量:1

共引文献17

同被引文献270

引证文献38

二级引证文献124

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部