摘要
介绍了浙江商会大厦空调冷热源、空调风系统及水系统的设计,计算分析了转轮全热回收机组的节能性,讨论了大厦空调水系统分区及水系统压力分布以及回收冷凝水作为冷却塔补水。
Presents the air conditioning cold and heat source, water system and air system design. Calculates and analyses the energy-saving efficiency of the rotary total heat exchanger, and discusses the zoning and the pressure distribution of the air conditioning water system; and the condensed water recycling for cooling tower make-up water.
出处
《暖通空调》
北大核心
2013年第2期83-86,共4页
Heating Ventilating & Air Conditioning
关键词
转轮全热回收
节能
超高层建筑
水系统压力分布
冷凝水
rotary total heat exchanger, energy efficiency, super high-rise building, pressuredistribution of water system, condensed water