摘要 目的运用共振频率分析仪评价微型种植体支抗的稳定性,为微型种植体早期加载提供理论依据。方法成年Beagle犬3只,分别在犬下颌两侧牙槽骨内各植入微型种植体支抗5枚。随机分为2组,实验组2周后加载100 g的水平力,加载时间为12周;对照组不加载。分别于微型种植体支抗植入后即刻、术后6周、术后10周、术后14周使用共振频率分析仪(Osstell Mento)测定2组微型种植体的稳定性,所得参数为微型种植体稳定值(ISQ)。采用SPSS17.0软件对数据进行分析。结果术后14周,2组微型种植体的成功率均为100%,2组微型种植体在各时间段的ISQ值无显著性差异(P>0.05),整体变化趋势表现为稳定性逐渐升高,于术后6周达到最大,其后逐渐减小,术后10周基本稳定,术后14周略有增加。结论 2周后负载不影响微型种植体支抗的稳定性。 Objective To evaluate the stability of early-loaded mini-implants using resonance frequency analysis(RFA).Methods In 3 adult Beagle dogs,5 miniscrew implants were installed on both sides of the mandible.In the experimental group the implants were loaded with 100g of force using Ni-Ti extension spring at 2 weeks after surgery;in the control group implants were not loaded with force.RFA was performed at 0,6,10,14 weeks after surgery for implants in both groups to get implant stability quotient(ISQ) values.P values for ISQ at all time were calculated by SPSS 17.0.Results No implants failed within 14 weeks.No significant difference in ISQ values was found between the two groups at all time points(P0.05).The two groups had the same changing mode of ISQ: increased gradually and get to peak value at 6 weeks after surgery,then decreased and kept stable at 10 weeks,and increased slightly afterward.Conclusion The healing for 2 weeks is enough for mini-implants anchorage loading.
出处 《同济大学学报(医学版)》 CAS 2012年第6期100-103,共4页 Journal of Tongji University(Medical Science)
基金 国家自然科学基金项目(81170942)
关键词 微型种植体支抗 共振频率分析 早期加载 稳定性 mini-implant anchage resonance frequency analysis early-loaded stability
  • 相关文献

参考文献12

  • 1Huang LH,Shotwell JL,Wang HL. Dental implants for orthodontic anchorage[J].American Journal of Orthodontics and Dentofacial Orthopedics,2005.713-722. 被引量:1
  • 2Rassmusson L,Meredith N,Kahnberg KE. Stability assessments and histology of titanium impiant placed simultaneously with autogenous onlay bone in the rabbit tibia[J].International Journal of Oral and Maxillofacial Surgery,1998,(03):229-325. 被引量:1
  • 3庄龙飞,张志勇,赖红昌.ITI种植体早期负重与传统负重稳定性的比较[J].上海口腔医学,2007,16(3):251-254. 被引量:11
  • 4阮征,黄远亮.共振频率分析在口腔种植实验与临床中的应用[J].口腔材料器械杂志,2010,19(3):157-160. 被引量:5
  • 5Aparicio C,Lang NP,Rangert B. Validity and clinical significance of biomechanical testing of implant/bone interface[J].Clinical Oral Implants Research,2006,(Suppl.2):2-7. 被引量:1
  • 6Schnelle MA,Beck FM,Jaynes RM. A radiographic evaluation of the availability of bone for placement of miniscrews[J].Angle Orthodontist,2004,(06):832-837. 被引量:1
  • 7吴晶,白玉兴,王邦康,高晓辉.微型种植体支抗愈合期稳定性的比较[J].中华口腔医学杂志,2006,41(4):226-227. 被引量:21
  • 8Deguchi T,Yamamoto T,Kanomi R. The use of small titanium screws for orthodontic anchorage[J].Journal of Dental Research,2003.377-381. 被引量:1
  • 9Meyer U,Joos U,Mythili J. Ultrastructural characterization of the implant / bone interface of immediately loaded dental implants[J].Biomaterials,2004,(10):1959-1967. 被引量:1
  • 10Freire JN,Silva NR,Gil JN. Histomorphologic and histomophometric evaluation of immediately and early loaded mini-implants for orthodontic anchorage[J].Am J Orthod Dento facia Orthop,2007,(06):704e1-704e9. 被引量:1

二级参考文献45

共引文献34

同被引文献37

引证文献3

二级引证文献15

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部