Research on the detuning system of a cooling electron beam for the dielectronic recombination experiment at CSRm

Research on the detuning system of a cooling electron beam for the dielectronic recombination experiment at CSRm
原文传递
导出
摘要 The storage ring equipped with an electron cooler is an ideal platform for dielectronic recombination (DR) experiments. In order to fulfill the requirement of DR measurements at the main Cooler Storage Ring, a detuning system for the precision control of the relative energy between the ion beam and the electron beam has been installed on the electron cooler device. The test run using 7.0 MeV/u C6+ beam was performed with recording the Schottky spectra and the ion beam currents. The influence of pulse heights and widths of the detuning voltage on the ion beam was analyzed. For the small pulse height, the experimental results from the Schottky spectra were in good agreement with the theoretical results. The frequency shift in the Schottky spectra was significantly reduced for the short pulse width. For the large pulse height, an oscillation phenomenon was observed and some effective ways to reduce the oscillation were pointed out. The detailed description of the phenomenon and the theoretical model based on the plasma oscillation was discussed in this paper. The overall results show that the new detuning system works properly, and could fulfill the requirements of future DR experiment. The storage ring equipped with an electron cooler is an ideal platform for dielectronic recombination (DR) experiments. In order to fulfill the requirement of DR measurements at the main Cooler Storage Ring, a detuning system for the precision control of the relative energy between the ion beam and the electron beam has been installed on the electron cooler device. The test run using 7.0 MeV/u C6+ beam was performed with recording the Schottky spectra and the ion beam currents. The influence of pulse heights and widths of the detuning voltage on the ion beam was analyzed. For the small pulse height, the experimental results from the Schottky spectra were in good agreement with the theoretical results. The frequency shift in the Schottky spectra was significantly reduced for the short pulse width. For the large pulse height, an oscillation phenomenon was observed and some effective ways to reduce the oscillation were pointed out. The detailed description of the phenomenon and the theoretical model based on the plasma oscillation was discussed in this paper. The overall results show that the new detuning system works properly, and could fulfill the requirements of future DR experiment.
出处 《Chinese Physics C》 SCIE CAS CSCD 2013年第1期117-124,共8页 中国物理C(英文版)
关键词 detuning system electron cooling Schottky spectrum plasma oscillation dielectronic recombination detuning system electron cooling Schottky spectrum plasma oscillation, dielectronic recombination
  • 相关文献

参考文献27

  • 1Muller A, Schippers S. ASP Conference Proceedings, 2001, 247:53. 被引量:1
  • 2Savin D W. J. Phys. Conf. Ser., 2007, 88:012071. 被引量:1
  • 3Badnell N R. J. Phys. Conf. Ser., 2007, 88:012070. 被引量:1
  • 4Brooks R L, Detla R U, Griem H R et al. Phys. Rev. Lett. 1978, 41:107. 被引量:1
  • 5Auerbach D, Cacak R, Caudano R etal. J. Phys. B: At. Mol Phys., 1977, 10:3797. 被引量:1
  • 6Mitchell J B A, Ng C T, Forand J L. Phys. Rev. Lett., 1983 50:335. 被引量:1
  • 7Dittner P F, Datz S, Miller P D et al. Phys. Rey. Lett., 1983 51:31. 被引量:1
  • 8Poth H. Phys. Rep., 1990, 196:135. 被引量:1
  • 9Poth H. Nature, 1990, 345:399. 被引量:1
  • 10Danared H. Phys. Scr., 1995, T59:121-125. 被引量:1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部