期刊文献+

尿液分析仪(UF-1000i)检测参数对尿路感染的诊断价值 被引量:7

Diagnostic efficiency of Sysmex UF-1000i automated urine analyzer for urinary tract infection
下载PDF
导出
摘要 目的评价尿液分析仪(UF-1000i)检测参数细菌计数以及WBC计数对尿路感染的诊断价值。方法前瞻性分析78例具有尿频、尿急和尿痛的患者尿液WBC计数和细菌计数,以及尿液干化学亚硝酸盐检测结果。采用受试者工作特征(ROC)曲线法分析WBC计数和细菌计数对尿路感染的诊断价值。以logisitic回归分析上述三个指标与尿路感染的关系是否独立。结果 WBC计数以及细菌计数诊断尿路感染的曲线下面积(95%可信区间)分别为0.90(0.83~0.97)和0.95(0.91~0.99),两者比较差异无统计学意义(P>0.05)。WBC计数的最佳诊断界值为46.45个/μl,此时的诊断敏感性(95%可信区间)以及特异性(95%可信区间)分别为0.79(0.61~0.91)和0.91(0.79~0.98)。细菌计数的最佳诊断界值为251.20个/ml,此时的诊断敏感性和特异性分别为0.91(0.76~0.98)和0.84(0.71~0.94)。亚硝酸盐的诊断敏感性和特异性分别为0.45和0.98。WBC计数、细菌计数和亚硝酸盐检测结果均与尿路感染独立相关。结论WBC计数、细菌计数和亚硝酸盐检测对尿路感染均有一定益处。其中WBC计数与细菌计数对尿路感染的诊断效能相似。三者对尿路感染的诊断价值互不重叠,联合检测可能有助于提高尿路感染的诊断准确性。 Objective To estimate the diagnostic performance of Sysmex UF-1000i automated urine analyzer test results for urinary tract infection(UTI).Methods Seventy-eight suspected UTI patients with the symptom of urorrhagia,urinary urgency or odynuria were prospectively enrolled and their urine samples were tested by Sysmex UF-1000i and URISYS2400.Receiver operating charac-teristic(ROC) curve analysis was applied to estimate the overall diagnostic performance of white blood cell count and bacteria count.Multivariable logistic regression model was used to evaluate the relationship between above laboratory characteristics and UTI.Results The area under curve(AUC)(95%CI) for WBC and bacteria counts were 0.90(0.83-0.97) and 0.95(0.91-0.99),respectively,without statistical significance between them(P0.05).For WBC count,the diagnostic sensitivity(95%CI) and specificity(95%CI) were 0.79(0.61-0.91) and 0.91(0.79-0.98),respectively,at the optimal threshold of 46.45/μl.Bacteria count had the diagnostic sensitivity(95%CI) of 0.91(0.76-0.98) and specificity(95%CI) of 0.84(0.71-0.94),at the optimal threshold of 251.20/ml.The diagnostic sensitivity and specificity were 0.45 and 0.98 for urine nitrates results.The WBC count,bacteria count and nitrates results were all independently associated with UTI.Conclusion WBC count,bacteria count and nitrates are effective diagnostic indicators for UTI.The diagnostic performances for WBC and bacteria count are comparable.The diagnostic value for these markers is not completely overlap,so combined use may improve the diagnostic accuracy.
出处 《临床军医杂志》 CAS 2013年第1期74-76,共3页 Clinical Journal of Medical Officers
关键词 尿路感染 诊断 尿液分析仪 urinary tract infection diagnosis automated urine analyzer
  • 相关文献

参考文献8

二级参考文献32

  • 1刘金彪,徐国鹏.尿亚硝酸盐试验诊断尿路感染的价值分析[J].中华医学丛刊,2004,4(8):44-45. 被引量:10
  • 2顾可梁.尿有形成分的识别与检查方法的选择[J].中华检验医学杂志,2005,28(6):572-575. 被引量:109
  • 3陈国强,沈培琼,沈燕,刘亚新,刘建栋.自动尿液分析仪筛检医院尿路感染临床意义探讨[J].中华医院感染学杂志,2006,16(12):1431-1433. 被引量:3
  • 4贝政平.内科疾病诊断标准.2版.北京:科学出版社,2007:237. 被引量:4
  • 5Kumar P, Clark M. Clinical Medicine(临床内科学).王德炳,译.6版.北京:北京大学医学出版社,2008:665-670. 被引量:2
  • 6Zaman Z, Roggeman S, Verhaegen J. Unsatisfactory performance of flow cytometer UF-100 and urine strips in predicting outcome of urine cultures. J Clin Microbiol,2001,39:4169-4171. 被引量:1
  • 7Okada H, Sakai Y , Miyazaki S, et al. Detection of significant bacteriuria by automated urinalysis using flow cytometry. J Clin Microbiol, 2000,38 : 2870-2872. 被引量:1
  • 8Buchsbaum GM, Albushies DT, Guziek DS, Utility of urine reagent strip in screening women with incontinence for urinary tract infection. Int Urogynecol J Pelvic Floor Dysfunct, 2004,15:391- 393. 被引量:1
  • 9Armengol CE, Hendley JO, Sehlager TA. Should we abandon standard microscopy when screening for urinary tract infections in young children. Pediatr Infect Dis J, 2001,20 : 1176-1177. 被引量:1
  • 10Nanos NE, Delanghe JR. Evaluation of SysmexUF-1000i for use in cerebrospinal fluid analysis. Clin Chim Acta,2008, 392:30-33. 被引量:1

共引文献122

同被引文献59

  • 1熊立凡,刘成立.临床基础[M].第4版.北京:人民卫生出版社,2007:193-199. 被引量:1
  • 2Evans R, Davidson MM, Sire LR, et al. Testing by Sysmex UF- 1000i flow cytometer and with bacterial culture in a diagnostic la- boratory : a comparison [ J ]. J Clin Path , 2006,59 ( 6 ) : 660 - 665. 被引量:1
  • 3Zaman Z, Roggerman S, Verhaegen J. Unsatisfactory performance of flow cytometer UF-100 and urine strips in predicting outcome of urine cultures[J]. J Clin Micro,2001,39:4169 -4171. 被引量:1
  • 4何发彬,李阳,阎衡,项贵明.UF-100尿液分析仪在尿路感染诊断中的应用[J].检验医学与临床,2008,5(2):76-77. 被引量:11
  • 5MANONI F,TINELLO A,FORNASIERO L,et al.Urine particle evaluation:acomparison between the UF-1000i and quan-titative microscopy[J].Clin Chem Lab Med,2010,48(8):1 107-1 111. 被引量:1
  • 6OKADA H,HORIE S,INOUE J,et al.The basic performance of bacteria counting for diagnosis of urinary tract infection using the fully automated urine particle analyzer UF-1000i[J].Sysmex Journal,2007,30(1):95-103. 被引量:1
  • 7KAMRAN K,KANCHANA M,PAT D,et al.UF-1000i flow cytometry is an effective screening methods for urine specimens[J].Diagn Micr Infec Dis,2011,75(69):130-136. 被引量:1
  • 8Hutchins RG,Vaden SL,Jacob ME,et al.Vaginal microbiota of spayed dogs with or without recurrent urinary tract infections[J].J veterinary internal med,2014,15:282-284. 被引量:1
  • 9Takaba K,Shigemura K,Osawa K,et al.Emergence of extended-spectrum β-lactamase-producing Escherichia coli in catheter-associated urinary tract infection in neurogenic bladder patients.[J].Am J infection control,2014,16:423-425. 被引量:1
  • 10Cai T,Mazzoli S,Migno S,et al.Development and validation of a nomogram predicting recurrence risk in women with symptomatic urinary tract infection[J].In J urol:official J Japan Urological Association,2014,22:219-221. 被引量:1

引证文献7

二级引证文献92

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部